西北药学杂志
西北藥學雜誌
서북약학잡지
2014年
6期
583-586
,共4页
苏敏%章志强%邓玉清%郝程
囌敏%章誌彊%鄧玉清%郝程
소민%장지강%산옥청%학정
盐酸贝那普利%氢氯噻嗪%含量测定%RP-HPLC
鹽痠貝那普利%氫氯噻嗪%含量測定%RP-HPLC
염산패나보리%경록새진%함량측정%RP-HPLC
benazepril hydrochloride%hydrochlorothiazide%content determination%RP-HPLC
目的:建立高效液相色谱法测定贝那普利氢氯噻嗪片的含量。方法采用 Ultimate AQ-C18柱(250 mm ×4.6 mm ,5μm);以四氢呋喃-水-冰醋酸(250 mL +750 mL +4 mL 加入四丁基溴化铵1.0 g)为流动相,检测波长:240 nm ;流速:1.5 mL ? min -1。结果盐酸贝那普利质量浓度在41.2~412.3μg ? mL -1范围内呈线性,r=0.9995,氢氯噻嗪质量浓度在51.0~509.6μg ? mL -1范围内呈线性,r=0.9998;盐酸贝那普利平均回收率在99.6%~101.6%之间,RSD 小于2%,氢氯噻嗪平均回收率在99.3%~100.7%之间,RSD 小于2%。结论该方法操作简便、准确、灵敏、重复性好,可用于贝那普利氢氯噻嗪片的质量控制。
目的:建立高效液相色譜法測定貝那普利氫氯噻嗪片的含量。方法採用 Ultimate AQ-C18柱(250 mm ×4.6 mm ,5μm);以四氫呋喃-水-冰醋痠(250 mL +750 mL +4 mL 加入四丁基溴化銨1.0 g)為流動相,檢測波長:240 nm ;流速:1.5 mL ? min -1。結果鹽痠貝那普利質量濃度在41.2~412.3μg ? mL -1範圍內呈線性,r=0.9995,氫氯噻嗪質量濃度在51.0~509.6μg ? mL -1範圍內呈線性,r=0.9998;鹽痠貝那普利平均迴收率在99.6%~101.6%之間,RSD 小于2%,氫氯噻嗪平均迴收率在99.3%~100.7%之間,RSD 小于2%。結論該方法操作簡便、準確、靈敏、重複性好,可用于貝那普利氫氯噻嗪片的質量控製。
목적:건립고효액상색보법측정패나보리경록새진편적함량。방법채용 Ultimate AQ-C18주(250 mm ×4.6 mm ,5μm);이사경부남-수-빙작산(250 mL +750 mL +4 mL 가입사정기추화안1.0 g)위류동상,검측파장:240 nm ;류속:1.5 mL ? min -1。결과염산패나보리질량농도재41.2~412.3μg ? mL -1범위내정선성,r=0.9995,경록새진질량농도재51.0~509.6μg ? mL -1범위내정선성,r=0.9998;염산패나보리평균회수솔재99.6%~101.6%지간,RSD 소우2%,경록새진평균회수솔재99.3%~100.7%지간,RSD 소우2%。결론해방법조작간편、준학、령민、중복성호,가용우패나보리경록새진편적질량공제。
Objective To establish an HPLC method for the determination of Benazepril Hydrochloride and Hydrochlorothiazide Tablets .Methods The chromatographic conditions were as follows :Ultimate AQ-C18 column (250 mm × 4 .6 mm 5 μm) ,mobile phase of butylene oxide-water-glacial acetic acid (250 mL + 750 mL + 4 mL ,add tetrabutylammonium bromide 1 .0 g ) ,detection wavelength at 240 nm ,and flow rate 1 .5 mL ? min - 1 .Results The calibration curve of benazepril hydrochloride was linear in the range of 41 .2-412 .3 μg ? mL - 1 ,r= 0 .999 5 ,while hydrochlorothiazide in the range of 51 .0-509 .6 μg ? mL - 1 ,r= 0 .999 8 .The average recovery of benazepril hydrochloride was between 99 .6% -101 .6% ,RSD < 2% .The average recovery of hydrochlorothiaz-ide was between 99 .3% -100 .7% ,RSD < 2% .Conclusion This method is simple ,accurate and reliable for the quality control of Benazepril Hydrochloride and Hydrochlorothiazide Tablets .