针对IEC 61850协议下,数字化电能表计量过程中的丢帧、误码和延时现象,介绍了一种基于插值算法的丢帧误码延时事件告警判断方法。先是通过解析计算计算出由丢帧误码延时引起的电能计量误差的大小,使人们对丢帧误码延时引起的误差的大小有一个准确清晰的认识,然后提出用插值算法计算其引起的电能误差大小,根据插值算法计算的电能相对误差大小判断丢包的严重程度,从而对数据的网络传输状况进行判断,并进行告警和事件记录。Matlab仿真验证结果表明:用插值算法能准确地计算出因丢帧误码延时引起的电能计量误差的大小,为丢帧误码延时事件的告警提供依据。
針對IEC 61850協議下,數字化電能錶計量過程中的丟幀、誤碼和延時現象,介紹瞭一種基于插值算法的丟幀誤碼延時事件告警判斷方法。先是通過解析計算計算齣由丟幀誤碼延時引起的電能計量誤差的大小,使人們對丟幀誤碼延時引起的誤差的大小有一箇準確清晰的認識,然後提齣用插值算法計算其引起的電能誤差大小,根據插值算法計算的電能相對誤差大小判斷丟包的嚴重程度,從而對數據的網絡傳輸狀況進行判斷,併進行告警和事件記錄。Matlab倣真驗證結果錶明:用插值算法能準確地計算齣因丟幀誤碼延時引起的電能計量誤差的大小,為丟幀誤碼延時事件的告警提供依據。
침대IEC 61850협의하,수자화전능표계량과정중적주정、오마화연시현상,개소료일충기우삽치산법적주정오마연시사건고경판단방법。선시통과해석계산계산출유주정오마연시인기적전능계량오차적대소,사인문대주정오마연시인기적오차적대소유일개준학청석적인식,연후제출용삽치산법계산기인기적전능오차대소,근거삽치산법계산적전능상대오차대소판단주포적엄중정도,종이대수거적망락전수상황진행판단,병진행고경화사건기록。Matlab방진험증결과표명:용삽치산법능준학지계산출인주정오마연시인기적전능계량오차적대소,위주정오마연시사건적고경제공의거。
In view of the phenomena of lost frames,error codes and time delay in the digital energy metering process in the IEC 61850 protocol,this paper introduced a judgment method for such events as lost frames,error codes and time delay,which was based on the interpolation algorithm. The energy metering error rate caused by lost frames,er-ror codes and time delay was first calculated through analytical calculation in order to have an accurate and clear awareness of it. And then this paper proposed using the interpolation algorithm to calculate the energy metering error. The results were used to judge the seriousness of package loss so as to judge the status of data transmission network, and thereby alert and event records should be generated. The Matlab simulation results showed that the interpolation algorithm could accurately calculate the energy metering error caused by lost frames,error codes and time delay and provide a basis for the event alert of lost frames,error codes and time delay in the digital energy metering process.