检验医学与临床
檢驗醫學與臨床
검험의학여림상
JOURNAL OF LABORATORY MEDICINE AND CLINICAL SCIENCES
2014年
21期
3006-3007,3010
,共3页
低剂量%头颅CT%健康体检者
低劑量%頭顱CT%健康體檢者
저제량%두로CT%건강체검자
low dose%brain CT%healthy examination
目的:探讨低剂量C T在健康体检者中的应用价值。方法将该院2010~2013年进行头颅C T平扫的健康体检者361例随机分成两组,分别给予头部常规剂量扫描方式和头部低剂量扫描方式进行头部轴位扫描。比较两种检查方法对疾病的检出率。结果常规剂量扫描方式检出颅脑血管畸形1例,腔隙性脑梗死3例,脑白质脱髓鞘改变2例,颅脑疾病检出率为3.0456%。低剂量扫描方式检出颅脑肿瘤1例,腔隙性脑梗死2例,蛛网膜囊肿1例,脑白质脱髓鞘改变1例,颅脑疾病检出率为3.0487%。两种方式的颅脑疾病检出率比较,差异无统计学意义(P>0.05);低剂量扫描方式受照放射剂量(容积CT剂量指数、剂量长度乘积)较常规剂量扫描方式降低25%。结论采用低剂量头颅CT扫描方法对健康体检者进行颅脑疾病的筛查,具有一定临床实用价值。
目的:探討低劑量C T在健康體檢者中的應用價值。方法將該院2010~2013年進行頭顱C T平掃的健康體檢者361例隨機分成兩組,分彆給予頭部常規劑量掃描方式和頭部低劑量掃描方式進行頭部軸位掃描。比較兩種檢查方法對疾病的檢齣率。結果常規劑量掃描方式檢齣顱腦血管畸形1例,腔隙性腦梗死3例,腦白質脫髓鞘改變2例,顱腦疾病檢齣率為3.0456%。低劑量掃描方式檢齣顱腦腫瘤1例,腔隙性腦梗死2例,蛛網膜囊腫1例,腦白質脫髓鞘改變1例,顱腦疾病檢齣率為3.0487%。兩種方式的顱腦疾病檢齣率比較,差異無統計學意義(P>0.05);低劑量掃描方式受照放射劑量(容積CT劑量指數、劑量長度乘積)較常規劑量掃描方式降低25%。結論採用低劑量頭顱CT掃描方法對健康體檢者進行顱腦疾病的篩查,具有一定臨床實用價值。
목적:탐토저제량C T재건강체검자중적응용개치。방법장해원2010~2013년진행두로C T평소적건강체검자361례수궤분성량조,분별급여두부상규제량소묘방식화두부저제량소묘방식진행두부축위소묘。비교량충검사방법대질병적검출솔。결과상규제량소묘방식검출로뇌혈관기형1례,강극성뇌경사3례,뇌백질탈수초개변2례,로뇌질병검출솔위3.0456%。저제량소묘방식검출로뇌종류1례,강극성뇌경사2례,주망막낭종1례,뇌백질탈수초개변1례,로뇌질병검출솔위3.0487%。량충방식적로뇌질병검출솔비교,차이무통계학의의(P>0.05);저제량소묘방식수조방사제량(용적CT제량지수、제량장도승적)교상규제량소묘방식강저25%。결론채용저제량두로CT소묘방법대건강체검자진행로뇌질병적사사,구유일정림상실용개치。
Objective To investigate the application value of low-dose head CT in the healthy examination . Methods 361 cases of healthy examination and conducting brain CT scan in our hospital from 2010 to 2013 were di-vided into the two groups at random .Then the axial scan on head in these two groups was performed by the routine scanning mode and the low-dose scanning respectively .The disease detection rates were compared between these two examination methods .Results In the routine dose scanning group ,1 case of brain vascular malformation ,3 cases of lacunar infarction and 2 cases of demyelination changes in white matter of brain were detected .The detection rate of brain diseases was 3 .045 6% .In the low-dose scanning group ,1 case of intracranial tumor ,2 cases of lacunar infarc-tion ,1 case of arachnoid cyst and 1 case of demyelination changes in white matter of brain were detected .The detec-tion rate of brain diseases was 3 .048 7% .There was no statistically significant difference in the disease detection rates between these two groups .The radiological dose(volume CT dose index ,dose-length product)of the low-dose scanning group was reduced by 25% than the routine dose scanning group .Conclusion Adopting the low-dose head CT scanning for screening the craniocerebral diseases in the healthy examination has certain clinical practical value .