目的:针对长期视频显示终端(VDT)作业引发的疲劳健康问题,设计VDT作业疲劳实验,探求实验前后脉搏参数的变化,为VDT作业疲劳的评价提供方法。方法:筛选30名健康在校大学生进行试验,受试者进行连续4 h的静态计算机游戏操作,每0.5 h采集2 min指端容积脉搏波数据,在实验前后对受试者进行疲劳症状问卷调查。分析提取脉率及脉率变异性参数、指脉搏波波形特征参数,并对比实验前后脉搏波波形图的变化。结果:以疲劳量表FS-14为标准,疲劳实验后受试者精神与躯体疲劳度均有所上升。以Rechichi提出的视疲劳判断标准,疲劳试验后受试者均处于视觉疲劳状态。受试者在VDT作业疲劳实验前后其心率(HR)指标具有显著性差异,且呈下降趋势;脉率变异性算得RMSSD及SDNN指标具有显著性差异,且呈上升趋势;指脉脉搏波波形特征参数K,在实验前后呈波动性上升趋势。结论:脉率及其部分变异性参数、部分脉搏特征参数具显著性变化,脉搏波波形图在VDT作业过程中有趋势性的变化,脉搏波在VDT作业疲劳的监测中具有应用价值,有望成为评价VDT疲劳状态的指标。
目的:針對長期視頻顯示終耑(VDT)作業引髮的疲勞健康問題,設計VDT作業疲勞實驗,探求實驗前後脈搏參數的變化,為VDT作業疲勞的評價提供方法。方法:篩選30名健康在校大學生進行試驗,受試者進行連續4 h的靜態計算機遊戲操作,每0.5 h採集2 min指耑容積脈搏波數據,在實驗前後對受試者進行疲勞癥狀問捲調查。分析提取脈率及脈率變異性參數、指脈搏波波形特徵參數,併對比實驗前後脈搏波波形圖的變化。結果:以疲勞量錶FS-14為標準,疲勞實驗後受試者精神與軀體疲勞度均有所上升。以Rechichi提齣的視疲勞判斷標準,疲勞試驗後受試者均處于視覺疲勞狀態。受試者在VDT作業疲勞實驗前後其心率(HR)指標具有顯著性差異,且呈下降趨勢;脈率變異性算得RMSSD及SDNN指標具有顯著性差異,且呈上升趨勢;指脈脈搏波波形特徵參數K,在實驗前後呈波動性上升趨勢。結論:脈率及其部分變異性參數、部分脈搏特徵參數具顯著性變化,脈搏波波形圖在VDT作業過程中有趨勢性的變化,脈搏波在VDT作業疲勞的鑑測中具有應用價值,有望成為評價VDT疲勞狀態的指標。
목적:침대장기시빈현시종단(VDT)작업인발적피로건강문제,설계VDT작업피로실험,탐구실험전후맥박삼수적변화,위VDT작업피로적평개제공방법。방법:사선30명건강재교대학생진행시험,수시자진행련속4 h적정태계산궤유희조작,매0.5 h채집2 min지단용적맥박파수거,재실험전후대수시자진행피로증상문권조사。분석제취맥솔급맥솔변이성삼수、지맥박파파형특정삼수,병대비실험전후맥박파파형도적변화。결과:이피로량표FS-14위표준,피로실험후수시자정신여구체피로도균유소상승。이Rechichi제출적시피로판단표준,피로시험후수시자균처우시각피로상태。수시자재VDT작업피로실험전후기심솔(HR)지표구유현저성차이,차정하강추세;맥솔변이성산득RMSSD급SDNN지표구유현저성차이,차정상승추세;지맥맥박파파형특정삼수K,재실험전후정파동성상승추세。결론:맥솔급기부분변이성삼수、부분맥박특정삼수구현저성변화,맥박파파형도재VDT작업과정중유추세성적변화,맥박파재VDT작업피로적감측중구유응용개치,유망성위평개VDT피로상태적지표。
Objective: To conduct an experiment of the visual display terminal work during which we analyzed the changing of the pulse wave signal to search the objective indices for diagnosing and assessing fatigue induced by the VDT work Methods: Thirty healthy undergraduates were required to attend the experiment during which the tester continued operating the static PC for 4 hours, and we collected the pulse wave of local blood volume in the finger tip for 2 minutes for each 30 minutes. The tester participated in the fatigue symptom inventory before and after the test. After the experiment, we analyzed the heart rate and pulse rate variability, the pulse wave characteristic values and the pulse contour which had been normalized. Results: By the standard of the Fatigue Scale-14, the fatigue degrees of the testers were all raising up. By the standard of Rechichi’s judging criterion, the testers were all in visual fatigue status after the experiment. There were significant differences of HR before and after the experiment which is clearly declining. The index RMSSD and SDNN of pulse rate variability had significant differences and were all raised up. The pulse contour characteristic value (K’) was increasing in the experiment. Conclusion:the heart rate, pulse rate variability and some parameters of pulse wave characteristic values had significant changes and the wave form of pulse had the tendency changes during the VDT work. The pulse wave has the promising prospect of applying to monitor the fatigue of the VDT works, also it is possible to put it into use as the index of evaluate the fatigue status.