农业工程学报
農業工程學報
농업공정학보
2014年
20期
259-267
,共9页
徐亚云%田宜水%赵立欣%姚宗路%侯书林%孟海波
徐亞雲%田宜水%趙立訢%姚宗路%侯書林%孟海波
서아운%전의수%조립흔%요종로%후서림%맹해파
秸秆%储存%运输%收集%模型%成本%能耗
秸稈%儲存%運輸%收集%模型%成本%能耗
갈간%저존%운수%수집%모형%성본%능모
straw%storage%transportation%collection%model%cost%energy consumption
为降低农作物秸秆收储运过程中成本和能耗损失,选择合适的收储运组合模式,促进秸秆规模化利用,该文建立了基于设备—人工—费用的秸秆收储运数学模型,并以华北平原为例,分析不同秸秆收储运模式(分为集中型、分散型;人工收集、机械收集等)和不同秸秆收集量对成本、能耗的影响以及人工、设备的实际需求。结果表明,秸秆收储运成本一般在120~260元/t之间,秸秆收储运能耗在(1.2~5.5)×105 kJ/t之间;田间机械收集比人工捡拾成本低,但所需设备投资较高,能耗明显升高;人工收集则需要大量的人工。收集方式相同时,集中型收储运模式成本和能耗都比分散型低;人工收集时秸秆收集量小于25万t或机械收集时收集量小于50万t,建议选择集中型收储运模式,否则选择分散型收储运模式。该文建立的收储运数学模型,为选择合适的秸秆收储运组合模式提供了参考依据;对促进秸秆能源利用,具有很大的指导意义。
為降低農作物秸稈收儲運過程中成本和能耗損失,選擇閤適的收儲運組閤模式,促進秸稈規模化利用,該文建立瞭基于設備—人工—費用的秸稈收儲運數學模型,併以華北平原為例,分析不同秸稈收儲運模式(分為集中型、分散型;人工收集、機械收集等)和不同秸稈收集量對成本、能耗的影響以及人工、設備的實際需求。結果錶明,秸稈收儲運成本一般在120~260元/t之間,秸稈收儲運能耗在(1.2~5.5)×105 kJ/t之間;田間機械收集比人工撿拾成本低,但所需設備投資較高,能耗明顯升高;人工收集則需要大量的人工。收集方式相同時,集中型收儲運模式成本和能耗都比分散型低;人工收集時秸稈收集量小于25萬t或機械收集時收集量小于50萬t,建議選擇集中型收儲運模式,否則選擇分散型收儲運模式。該文建立的收儲運數學模型,為選擇閤適的秸稈收儲運組閤模式提供瞭參攷依據;對促進秸稈能源利用,具有很大的指導意義。
위강저농작물갈간수저운과정중성본화능모손실,선택합괄적수저운조합모식,촉진갈간규모화이용,해문건립료기우설비—인공—비용적갈간수저운수학모형,병이화북평원위례,분석불동갈간수저운모식(분위집중형、분산형;인공수집、궤계수집등)화불동갈간수집량대성본、능모적영향이급인공、설비적실제수구。결과표명,갈간수저운성본일반재120~260원/t지간,갈간수저운능모재(1.2~5.5)×105 kJ/t지간;전간궤계수집비인공검습성본저,단소수설비투자교고,능모명현승고;인공수집칙수요대량적인공。수집방식상동시,집중형수저운모식성본화능모도비분산형저;인공수집시갈간수집량소우25만t혹궤계수집시수집량소우50만t,건의선택집중형수저운모식,부칙선택분산형수저운모식。해문건립적수저운수학모형,위선택합괄적갈간수저운조합모식제공료삼고의거;대촉진갈간능원이용,구유흔대적지도의의。
In order to select appropriate mode of crop straw’s collection-storage-transportation, and promote the large-scale use of straw resources, the mathematical model about straw’s collection, storage and transportation was established, which was based on the equipment, manpower, and cost on the North China Plain. By analyzing different modes about straw’s collection-storage-transportation (which was divided into centralized model, decentralized mode; collected by manpower, collected by machinery), the effect of cost and energy consumption were different. Because of the different amounts of straw collection, manpower and equipments were demanded in mathematical models. The results showed that the cost of straw’s collection-storage-transportation was 120- 260 Yuan/t, the fuel consumption of straw’s collection-storage-transportation was 1.2×105 - 5.5×105 kJ/t. While using machinery to collected straw in filed, the cost was lower than that by manpower; but the required equipment number was significantly more than thatneeded by manpower. Meanwhile, the energy consumption of equipment was significantly increased. On the contrary, collecting straw in filed by manpower needs a lot of manpower. The calculated results showed that the cost and energy consumption of centralized mode about equipment-manpower- cost was lower than decentralized mode when collecting by the same manner. Compared to the manpower collection, collection by machinery can reduce the total cost, but the initial investment was higher and the capacity in solving employment problem was lower. When the amount of crop straw collection increased from 5×104 to 50×104 t, the unit cost of mode A and B was monotonically increasing. As to mode C and D, it declined quickly from 5×104 to 25×104 t, then rose gradually from 25×104 to 50×104 t. Therefore, it can be concluded that the collection methods affected cost extremely. Collecting straw by manpower, the mode of A and C curved intersect at 250 000 t; Or else, the mode of B and D curved intersect at 500 000 t. When the collected amount of crop straw increased from 5×104 to 50×104 t, the unit energy consumptions of mode A and B increased, with slow upward trend rate; On the contrary, from 5×104 to 25×104 t straw collection, the unit energy consumption of mode C and D was decreasing, when the collected amount of crop straw was 18×104 and 12×104 t, the unit energy consumption curves of mode B and C2 could intersect; Similarly, the unit energy consumption curves of mode A2 and C1 also could intersect. In this circumstance, when the collected amount was less than the intersection, the energy consumption of mode B and A2 was lower than mode C2 and C1. Therefore, the energy consumption of centralized mode is lower when the crop straw amount collected is less, it is recommended to choose centralized mode; Otherwise, decentralized mode is the better choice.