中国临床药理学杂志
中國臨床藥理學雜誌
중국림상약이학잡지
THE CHINESE JOURNAL OF CLINICAL PHARMACOLOGY
2014年
5期
448-450
,共3页
宋新文%汪洋%刘炘%许琼%彭静
宋新文%汪洋%劉炘%許瓊%彭靜
송신문%왕양%류흔%허경%팽정
甲氨蝶呤%固相萃取%高效液相色谱法
甲氨蝶呤%固相萃取%高效液相色譜法
갑안접령%고상췌취%고효액상색보법
methotrexate%solid phase extraction%HPLC
目的:建立一种快速、准确测定人血清中甲氨蝶呤浓度的高效液相色谱法。方法色谱柱为 Hypersil C18,流动相为甲醇-乙腈-磷酸盐缓冲液(2∶7∶91),流速为0.8 mL· min-1,检测波长313 nm;血清样品上SPE柱,以含甲醇-乙腈-磷酸盐缓冲液(50∶50∶250)为洗脱剂,收集洗脱液直接进样测定。结果甲氨蝶呤血清样品线性范围为0.03~50.00μg· mL-1,2组低、中、高不同浓度(A组:3.41,6.82,27.27μg· mL-1;B组:0.05,0.21,0.85μg· mL-1)方法回收率均大于97%。日内、日间RSD均小于5%。结论本方法准确性好、灵敏度高、操作简便,完全可满足儿科临床甲氨蝶呤血药浓度监测需要。
目的:建立一種快速、準確測定人血清中甲氨蝶呤濃度的高效液相色譜法。方法色譜柱為 Hypersil C18,流動相為甲醇-乙腈-燐痠鹽緩遲液(2∶7∶91),流速為0.8 mL· min-1,檢測波長313 nm;血清樣品上SPE柱,以含甲醇-乙腈-燐痠鹽緩遲液(50∶50∶250)為洗脫劑,收集洗脫液直接進樣測定。結果甲氨蝶呤血清樣品線性範圍為0.03~50.00μg· mL-1,2組低、中、高不同濃度(A組:3.41,6.82,27.27μg· mL-1;B組:0.05,0.21,0.85μg· mL-1)方法迴收率均大于97%。日內、日間RSD均小于5%。結論本方法準確性好、靈敏度高、操作簡便,完全可滿足兒科臨床甲氨蝶呤血藥濃度鑑測需要。
목적:건립일충쾌속、준학측정인혈청중갑안접령농도적고효액상색보법。방법색보주위 Hypersil C18,류동상위갑순-을정-린산염완충액(2∶7∶91),류속위0.8 mL· min-1,검측파장313 nm;혈청양품상SPE주,이함갑순-을정-린산염완충액(50∶50∶250)위세탈제,수집세탈액직접진양측정。결과갑안접령혈청양품선성범위위0.03~50.00μg· mL-1,2조저、중、고불동농도(A조:3.41,6.82,27.27μg· mL-1;B조:0.05,0.21,0.85μg· mL-1)방법회수솔균대우97%。일내、일간RSD균소우5%。결론본방법준학성호、령민도고、조작간편,완전가만족인과림상갑안접령혈약농도감측수요。
Objective To establish a rapid and accurate HPLC method for determination the concentration of methotrexate in human serum.Methods Chromatographic column was Hypersil C 18 column; mobile phase was methanol ,acetonitrile and phosphate buffer (2∶7∶91 ) , a flow rate was 0.8 mL· min-1;detection wavelength was 313 nm.Serum sam-ple was injected into SPE column.Methanol/acetonitrile/phosphate buff-er ( 50∶50∶250 ) was used as the eluent , and the collection of eluent was detected directly.Results The linear range of methotrexate in serum samples was 0.03-50.00 μg · mL-1 , coefficient of recoveries of low , medium and high concentrations in two groups ( group A:3.41 , 6.82 , 27.27 μg· mL-1;group B:0.05, 0.21, 0.85 μg· mL-1)were higher than 97%.Inter day and inner day RSD were less than 5%.Conclusion This method has good accuracy , high sensitivity , convenient opera-tion.It can fully satisfy the requirement of concentration monitoring of methotrexate in the pediatric clinical practice.