检验医学
檢驗醫學
검험의학
LABORATORY MEDICINE
2014年
11期
1169-1174
,共6页
顾伟鸣%杨阳%吴磊%郭玮%宋斌斌%邓安梅%王庆忠
顧偉鳴%楊暘%吳磊%郭瑋%宋斌斌%鄧安梅%王慶忠
고위명%양양%오뢰%곽위%송빈빈%산안매%왕경충
梅毒%血清学%检测性能%评估方案%即时检验%最低检测限
梅毒%血清學%檢測性能%評估方案%即時檢驗%最低檢測限
매독%혈청학%검측성능%평고방안%즉시검험%최저검측한
Syphilis serology%Assay performance%Evaluation protocol%Point-of-care testing%Lower limit of detection
目的:制定优化的梅毒血清学试剂的评估方案,探讨新方案在发现试剂检测性能特征的价值。方法优化的评估方案首次引入最低检出限、抗干扰性、稳定性等技术参数,采用国际抗梅毒标准血清进行测量值溯源,选择国产梅毒血清学试剂及相对应的进口试剂共6种,以多中心方式进行检测性能的评价。结果456例明确诊断样品的定性试验,梅毒免疫层析法结果与诊断100%符合;其它4种梅毒筛查试剂相互间虽然敏感性和特异性差异无统计学意义,但存在不同程度的假阳性和假阴性;最低检测限浓度由高到低分别是筛查试剂、梅毒螺旋体凝集法、免疫层析法、和酶联免疫法/化学发光法;两种促凝真空采血器96.88%干扰筛查试剂。结论国产梅毒血清学试剂的检测性能媲美进口产品。免疫层析试剂与临床诊断高度符合,且敏感性水平超过了传统的方法,为推广应用奠定了基础。新的梅毒血清学试剂的评估方案,更完整地反映以往被忽略的影响因素。
目的:製定優化的梅毒血清學試劑的評估方案,探討新方案在髮現試劑檢測性能特徵的價值。方法優化的評估方案首次引入最低檢齣限、抗榦擾性、穩定性等技術參數,採用國際抗梅毒標準血清進行測量值溯源,選擇國產梅毒血清學試劑及相對應的進口試劑共6種,以多中心方式進行檢測性能的評價。結果456例明確診斷樣品的定性試驗,梅毒免疫層析法結果與診斷100%符閤;其它4種梅毒篩查試劑相互間雖然敏感性和特異性差異無統計學意義,但存在不同程度的假暘性和假陰性;最低檢測限濃度由高到低分彆是篩查試劑、梅毒螺鏇體凝集法、免疫層析法、和酶聯免疫法/化學髮光法;兩種促凝真空採血器96.88%榦擾篩查試劑。結論國產梅毒血清學試劑的檢測性能媲美進口產品。免疫層析試劑與臨床診斷高度符閤,且敏感性水平超過瞭傳統的方法,為推廣應用奠定瞭基礎。新的梅毒血清學試劑的評估方案,更完整地反映以往被忽略的影響因素。
목적:제정우화적매독혈청학시제적평고방안,탐토신방안재발현시제검측성능특정적개치。방법우화적평고방안수차인입최저검출한、항간우성、은정성등기술삼수,채용국제항매독표준혈청진행측량치소원,선택국산매독혈청학시제급상대응적진구시제공6충,이다중심방식진행검측성능적평개。결과456례명학진단양품적정성시험,매독면역층석법결과여진단100%부합;기타4충매독사사시제상호간수연민감성화특이성차이무통계학의의,단존재불동정도적가양성화가음성;최저검측한농도유고도저분별시사사시제、매독라선체응집법、면역층석법、화매련면역법/화학발광법;량충촉응진공채혈기96.88%간우사사시제。결론국산매독혈청학시제적검측성능비미진구산품。면역층석시제여림상진단고도부합,차민감성수평초과료전통적방법,위추엄응용전정료기출。신적매독혈청학시제적평고방안,경완정지반영이왕피홀략적영향인소。
Objective To design and optimize performance evaluation protocol for syphilis serologic assays,and to investigate the significance of new protocol for discovering the characteristics of assay performance.Methods Technical parameters,such as lower limit of detection,interference and stability were introduced firstly into the optimized performance evaluation protocol,and 6 domestic and imported assay reagents for syphilis serology were evaluated according to the protocol by multi-center joint study.Results The qualitative test for 456 definite specimens showed 1 00% agreement result between point-of-care testing and clinical diagnostic test,and exhibited various degrees of false positive and false negative results among the other 4 screening assays,although their sensitivity and specificity had no statistical difference.The lower limits of detection of the reagents descended from high to low in the order of screening assays were treponema pallidum particle agglutination assay,point-of-care testing and enzyme-linked immunosorbent assay/chemiluminescence immunoassay.Two brands of procoagulant vacuum blood collection tubes interfered with non-specific antibody detection reagent for syphilis in a 96.88% proportion.Conclusions The study shows that the performance of domestic syphilis serologic assays is comparable with that of imported ones.The result by point-of-care testing exhibits a high agreement with clinical diagnostic test result,and its sensitivity is better than that of the traditional method,which lays a foundation for spreading in clinical application.The optimized performance evaluation protocol for syphilis serologic assays would reflect assay performance better.