罕遇地震%底框砌体房屋%弹塑性分析%裂缝
罕遇地震%底框砌體房屋%彈塑性分析%裂縫
한우지진%저광체체방옥%탄소성분석%렬봉
rare earthquake%bottom frame masonry structure%elastic-plastic analysis%crack
以底框砌体结构房屋为研究对象,建立有限元分析模型,对结构施加调幅后的EI-CENTRO地震波进行大震作用下结构的弹塑性时程分析;并通过添加抗震墙,建立底部框剪有限元分析模型,对比分析了添加抗震墙前后结构裂缝变化趋势。分析结果表明:原结构底层框架部分出现严重的弹塑性变形集中,层间位移大,层间位移角不能满足现行规范的抗震设防要求;底层柱上下端、过渡层横墙下部附近是结构薄弱环节;添加抗震墙后结构底层位移反应减小,但过渡层层间位移增大,墙体也比原结构开裂严重,在第三层出现了类似原结构过渡层的交叉裂缝,说明了需要合理添加抗震墙以防薄弱层发生转移。研究结果可为此类房屋的破坏机理研究及抗震性能评价提供技术参考。
以底框砌體結構房屋為研究對象,建立有限元分析模型,對結構施加調幅後的EI-CENTRO地震波進行大震作用下結構的彈塑性時程分析;併通過添加抗震牆,建立底部框剪有限元分析模型,對比分析瞭添加抗震牆前後結構裂縫變化趨勢。分析結果錶明:原結構底層框架部分齣現嚴重的彈塑性變形集中,層間位移大,層間位移角不能滿足現行規範的抗震設防要求;底層柱上下耑、過渡層橫牆下部附近是結構薄弱環節;添加抗震牆後結構底層位移反應減小,但過渡層層間位移增大,牆體也比原結構開裂嚴重,在第三層齣現瞭類似原結構過渡層的交扠裂縫,說明瞭需要閤理添加抗震牆以防薄弱層髮生轉移。研究結果可為此類房屋的破壞機理研究及抗震性能評價提供技術參攷。
이저광체체결구방옥위연구대상,건립유한원분석모형,대결구시가조폭후적EI-CENTRO지진파진행대진작용하결구적탄소성시정분석;병통과첨가항진장,건립저부광전유한원분석모형,대비분석료첨가항진장전후결구렬봉변화추세。분석결과표명:원결구저층광가부분출현엄중적탄소성변형집중,층간위이대,층간위이각불능만족현행규범적항진설방요구;저층주상하단、과도층횡장하부부근시결구박약배절;첨가항진장후결구저층위이반응감소,단과도층층간위이증대,장체야비원결구개렬엄중,재제삼층출현료유사원결구과도층적교차렬봉,설명료수요합리첨가항진장이방박약층발생전이。연구결과가위차류방옥적파배궤리연구급항진성능평개제공기술삼고。
Taking the house of bottom frame masonry structure as a study object a finite element model is es -tablished this paper uses EI-CENTRO seismic waves after amplituding and undertakes structural elastic-plastic analysis under a rare earthquake is performed .Meanwhile , by adding shear walls a finite element model of bot-tom frame-shear masonry structure was established and crack development before and after adding shear walls was compared .The analysis result shows:the bottom frame of the original structure induces serious concentra-tion of elastic-plastic deformation and the angle of displacement cannot meet the demand of earthquake fortifi -cation in current code;the ends of the bottom frame column the lower part of the cross wall in the transition layer are weak components of this structure; after adding shear walls , the bottom floor displacement reaction decreases , but the transition layer displacement reaction increases;cross cracks in the third layer are similar to the transition layer of the original structure , which indicates the need to add reasonable shear walls .