中国特种设备安全
中國特種設備安全
중국특충설비안전
CHINA SPECIAL EQUIPMENT SAFETY
2013年
9期
63-65
,共3页
常压塔%衬板%裂纹%鼓胀%坑蚀%机理%处理措施
常壓塔%襯闆%裂紋%鼓脹%坑蝕%機理%處理措施
상압탑%츤판%렬문%고창%갱식%궤리%처리조시
Atmospheric tower%Liner%Crack Bulging%Pitting%Mechanism%Treatment measures
叙述了茂名石化公司二蒸馏装置常压塔进料段的坑蚀和鼓胀情况,分析了其腐蚀机理和原因。介绍了采取的处理措施。
敘述瞭茂名石化公司二蒸餾裝置常壓塔進料段的坑蝕和鼓脹情況,分析瞭其腐蝕機理和原因。介紹瞭採取的處理措施。
서술료무명석화공사이증류장치상압탑진료단적갱식화고창정황,분석료기부식궤리화원인。개소료채취적처리조시。
The pitting and bulging of the feed zone at the atmospheric tower in the two distillation unit of the Maoming Petrochemical Company was described, the corrosion mechanism and its causes were analyzed, and Measures undertaken to deal was introduced.