关节成形术,置换,髋%放射摄影术%髋臼
關節成形術,置換,髖%放射攝影術%髖臼
관절성형술,치환,관%방사섭영술%관구
Arthroplasty,replacement,hip%Radiography%Acetabulum
目的:在全髋关节置换术(THR)中,人工髋关节的稳定性取决于髋臼假体的精确安置。适当的髋臼角度,能够避免发生髋关节脱位以及撞击征和关节过度磨损,进而维持人工关节的活动度和稳定性。方法应用术中C臂X光机移位测量髋臼的前倾角、外展角来确定术中髋臼假体的置入角度,并与手术前后测定的髋臼位相参数和传统髋臼假体定位器置入假体的患者全髋术后的髋臼位相参数对比,探讨这种测定方法的应用价值。结果髋臼杯的精确安置可以使髋关节的生物力学得以优化,减少髋关节的脱位率和避免撞击。结论术中准确的纠正骨盆的前后倾斜、内外旋转和外展内收,以及髋臼杯的精确安放,可以提高假体置换术手术质量,减少术后脱位、假体撞击、关节活动受限以及聚乙烯磨损等并发症,促使人工关节的保存率得以延长。
目的:在全髖關節置換術(THR)中,人工髖關節的穩定性取決于髖臼假體的精確安置。適噹的髖臼角度,能夠避免髮生髖關節脫位以及撞擊徵和關節過度磨損,進而維持人工關節的活動度和穩定性。方法應用術中C臂X光機移位測量髖臼的前傾角、外展角來確定術中髖臼假體的置入角度,併與手術前後測定的髖臼位相參數和傳統髖臼假體定位器置入假體的患者全髖術後的髖臼位相參數對比,探討這種測定方法的應用價值。結果髖臼杯的精確安置可以使髖關節的生物力學得以優化,減少髖關節的脫位率和避免撞擊。結論術中準確的糾正骨盆的前後傾斜、內外鏇轉和外展內收,以及髖臼杯的精確安放,可以提高假體置換術手術質量,減少術後脫位、假體撞擊、關節活動受限以及聚乙烯磨損等併髮癥,促使人工關節的保存率得以延長。
목적:재전관관절치환술(THR)중,인공관관절적은정성취결우관구가체적정학안치。괄당적관구각도,능구피면발생관관절탈위이급당격정화관절과도마손,진이유지인공관절적활동도화은정성。방법응용술중C비X광궤이위측량관구적전경각、외전각래학정술중관구가체적치입각도,병여수술전후측정적관구위상삼수화전통관구가체정위기치입가체적환자전관술후적관구위상삼수대비,탐토저충측정방법적응용개치。결과관구배적정학안치가이사관관절적생물역학득이우화,감소관관절적탈위솔화피면당격。결론술중준학적규정골분적전후경사、내외선전화외전내수,이급관구배적정학안방,가이제고가체치환술수술질량,감소술후탈위、가체당격、관절활동수한이급취을희마손등병발증,촉사인공관절적보존솔득이연장。
Objective In the total hip replacement, the stability of the artificial hip joint depends on the precise replacement of the acetabular prosthesis. The appropriate acetabular angle can avoid dislocation , impact as well as exces-sive wear of the hip joint. And then it helps maintain the mobility and the stability of the artificial hip joint. Methods Dur-ing the practical surgery, the C-arm X-ray machine was used to measure the anteversion and the abduction angle size of the acetabular to determine the displacement angle of the artificial hip joint. Then , the acetabular phase parameters measured before and after the surgery were compared with that of the traditional surgery. The application value of this measurement was explored through the comparison. Results The precise displacement of the acetabular cup could optimize the biomechanics of the hip joint. It could also lessen the dislocation rate and avoid impact of the hip joint. Conclusion In the operation, if the front and rear tilt, the internal and external rotation as well as the abduction adduction of the hip joint are precisely corrected, and if the acetabular cup is accurately displaced, they can improve the quality of the prosthetic arthroplasty. They can help reduce the postoperative dislocation , prosthesis impact, joint motion limitation, polyethylene wear and other complications. They prolong the saving rate of the artificial joint.