对某供电局一起配电网自动化终端设备起火事故进行分析,现场检查发现箱内电池炸开,大部分设备已被熏黑,结合历史数据分析认为电池爆炸起火是造成该次终端箱烧毁的主要原因。为此,对引发火灾的锂离子电池进行抽样诊断分析,发现该电池的设计存在缺陷,电芯的数量和容量选择均存在问题,此外缺乏过充、过放、过温等报警装置;对电池解体进行扫描电子显微镜(scanning electron microscope,SEM)测试,发现电极表面有铜析出,认为这可能是由于电池过放电导致的,这使得电芯发生内短路,并最终引发起火事故。最后,总结了事故的经验和教训,对在电力系统等新场合应用锂离子电池提出建议。
對某供電跼一起配電網自動化終耑設備起火事故進行分析,現場檢查髮現箱內電池炸開,大部分設備已被熏黑,結閤歷史數據分析認為電池爆炸起火是造成該次終耑箱燒燬的主要原因。為此,對引髮火災的鋰離子電池進行抽樣診斷分析,髮現該電池的設計存在缺陷,電芯的數量和容量選擇均存在問題,此外缺乏過充、過放、過溫等報警裝置;對電池解體進行掃描電子顯微鏡(scanning electron microscope,SEM)測試,髮現電極錶麵有銅析齣,認為這可能是由于電池過放電導緻的,這使得電芯髮生內短路,併最終引髮起火事故。最後,總結瞭事故的經驗和教訓,對在電力繫統等新場閤應用鋰離子電池提齣建議。
대모공전국일기배전망자동화종단설비기화사고진행분석,현장검사발현상내전지작개,대부분설비이피훈흑,결합역사수거분석인위전지폭작기화시조성해차종단상소훼적주요원인。위차,대인발화재적리리자전지진행추양진단분석,발현해전지적설계존재결함,전심적수량화용량선택균존재문제,차외결핍과충、과방、과온등보경장치;대전지해체진행소묘전자현미경(scanning electron microscope,SEM)측시,발현전겁표면유동석출,인위저가능시유우전지과방전도치적,저사득전심발생내단로,병최종인발기화사고。최후,총결료사고적경험화교훈,대재전력계통등신장합응용리리자전지제출건의。
One fire accident of automation terminal unit (DTU)of power distribution network in some power supply bureau was analyzed.Lithium ion battery in the box was found to be exploded and most equipments were sooty on the scene.Com-bining with historical data,it was considered that the main reason for this accident was explosion and fire breakout of the lithium ion battery.Therefore,the lithium ion battery causing fire accident was sampled and diagnosed and it was discovered defects in its design.There were problems in number and capacity of the cell as well.In addition,lack of over-charge,over-discharge and over-temperature alarm devices was also discovered.Scanning electron microscope testing was conducted on the disintegrated battery and copper was found on the surface of electrodes.It was considered to be caused for reason of o-ver-discharge of the battery which also resulted in internal short-circuit of the cell and finally caused fire accident.Accident experience and lesson was summarized and suggestions on applying lithium ion battery in power system were proposed.