目的:评价改良Hardinge入路全髋置换在双下肢等长控制中的应用效果。方法对行改良Hardinge入路全髋置换及术中用自创等长测量方法进行双下肢等长控制并获1年以上随访的100例患者进行总结,采用Harris标准对髋关节功能进行评定。结果100例患者均获随访,时间12~60(26±2.1)个月。 Harris评分:优92例,良7例,可1例,优良率99%。下肢等长95例,下肢不等长在0.3~0.5 cm之间3例,相差0.6cm 1例,相差0.8 cm 1例。结论该入路暴露好,假体安装定位好,因术中下肢基本处于标准侧卧位,易于控制下肢长度,特别适用自创的术中精确测量调控双下肢等长的手术方法,可减少因体位原因导致的误差,术后外展肌恢复快,总体恢复良好。
目的:評價改良Hardinge入路全髖置換在雙下肢等長控製中的應用效果。方法對行改良Hardinge入路全髖置換及術中用自創等長測量方法進行雙下肢等長控製併穫1年以上隨訪的100例患者進行總結,採用Harris標準對髖關節功能進行評定。結果100例患者均穫隨訪,時間12~60(26±2.1)箇月。 Harris評分:優92例,良7例,可1例,優良率99%。下肢等長95例,下肢不等長在0.3~0.5 cm之間3例,相差0.6cm 1例,相差0.8 cm 1例。結論該入路暴露好,假體安裝定位好,因術中下肢基本處于標準側臥位,易于控製下肢長度,特彆適用自創的術中精確測量調控雙下肢等長的手術方法,可減少因體位原因導緻的誤差,術後外展肌恢複快,總體恢複良好。
목적:평개개량Hardinge입로전관치환재쌍하지등장공제중적응용효과。방법대행개량Hardinge입로전관치환급술중용자창등장측량방법진행쌍하지등장공제병획1년이상수방적100례환자진행총결,채용Harris표준대관관절공능진행평정。결과100례환자균획수방,시간12~60(26±2.1)개월。 Harris평분:우92례,량7례,가1례,우량솔99%。하지등장95례,하지불등장재0.3~0.5 cm지간3례,상차0.6cm 1례,상차0.8 cm 1례。결론해입로폭로호,가체안장정위호,인술중하지기본처우표준측와위,역우공제하지장도,특별괄용자창적술중정학측량조공쌍하지등장적수술방법,가감소인체위원인도치적오차,술후외전기회복쾌,총체회복량호。
Objective To evaluate the application of improved Hardinge approach in total hip arthroplasty in limb length control system. Methods The improved Hardinge approach and length measurement methods were used for total hip arthroplasty. 100 cases were followed up for more than 1 year. The Harris standard was used to evaluate the hip joint function. Results All 100 cases were followed up for 12~60 (26 ± 2. 1) months. The results were excel-lent in 92 cases, good in 7, and fair in 1, the excellent-good rate was 99%. 95 cases got equalized legs, leg length discrepancy was between 0. 3~0. 5 cm in 3 cases, 0. 6 cm in 1 case and 0. 8 cm in 1. Conclusions This approach provides good exposure and good positioning of prosthesis. Lower limb length can be controlled in standard lateral po-sition, especially with our own long intraoperative surgical method to accurately measure the regulation of both lower extremities. Abductor can get faster recovery after surgery, which facilitate good recovery.