临床骨科杂志
臨床骨科雜誌
림상골과잡지
JOURNAL OF CLINICAL ORTHOPAEDICS
2014年
6期
659-663
,共5页
曾俊%林旭%郭勇%钟泽莅%曹林虎%谭伦
曾俊%林旭%郭勇%鐘澤蒞%曹林虎%譚倫
증준%림욱%곽용%종택리%조림호%담륜
计算机辅助%个体化%经皮%舟骨骨折%空心螺钉
計算機輔助%箇體化%經皮%舟骨骨摺%空心螺釘
계산궤보조%개체화%경피%주골골절%공심라정
computer-assisted%individualization%percutaneous%scaphoid fracture%cannulated screws
目的:利用Mimics软件设计一种腕舟骨骨折个体化掌侧经皮空心螺钉置钉技术。方法将24例成人腕舟骨骨折腕关节CT扫描数据导入Mimics软件,在Mimics软件中进行腕关节三维重建,模拟舟骨手术,制定舟骨个体化置钉参数并模拟置钉,据此参数在腕舟骨上经皮置钉。术后行腕关节CT扫描,验证置钉准确性。结果 Mimics重建图像和CT扫描的腕舟骨参数差异无统计学意义,能准确反映舟骨三维立体结构。用该方法对24例成人腕舟骨骨折行经皮空心螺钉固定,术后CT显示螺钉位置良好,随访腕关节功能良好。结论用Mimics软件对腕关节进行三维重建,模拟手术,测量、制订详细合理的个体化置钉参数,可优化手术方案与方式,减少并发症,降低手术风险,提高临床治疗效果。
目的:利用Mimics軟件設計一種腕舟骨骨摺箇體化掌側經皮空心螺釘置釘技術。方法將24例成人腕舟骨骨摺腕關節CT掃描數據導入Mimics軟件,在Mimics軟件中進行腕關節三維重建,模擬舟骨手術,製定舟骨箇體化置釘參數併模擬置釘,據此參數在腕舟骨上經皮置釘。術後行腕關節CT掃描,驗證置釘準確性。結果 Mimics重建圖像和CT掃描的腕舟骨參數差異無統計學意義,能準確反映舟骨三維立體結構。用該方法對24例成人腕舟骨骨摺行經皮空心螺釘固定,術後CT顯示螺釘位置良好,隨訪腕關節功能良好。結論用Mimics軟件對腕關節進行三維重建,模擬手術,測量、製訂詳細閤理的箇體化置釘參數,可優化手術方案與方式,減少併髮癥,降低手術風險,提高臨床治療效果。
목적:이용Mimics연건설계일충완주골골절개체화장측경피공심라정치정기술。방법장24례성인완주골골절완관절CT소묘수거도입Mimics연건,재Mimics연건중진행완관절삼유중건,모의주골수술,제정주골개체화치정삼수병모의치정,거차삼수재완주골상경피치정。술후행완관절CT소묘,험증치정준학성。결과 Mimics중건도상화CT소묘적완주골삼수차이무통계학의의,능준학반영주골삼유입체결구。용해방법대24례성인완주골골절행경피공심라정고정,술후CT현시라정위치량호,수방완관절공능량호。결론용Mimics연건대완관절진행삼유중건,모의수술,측량、제정상세합리적개체화치정삼수,가우화수술방안여방식,감소병발증,강저수술풍험,제고림상치료효과。
Objective To provide a individualization volar percutaneous cannulated screws fixation with the help of Mimics-assisted design in carpal scaphoid fracture surgery. Methods Three-dimensional reconstruction of 24 CT scanned adult carpal scaphoid fractures were performed by using Mimics software. The operations were analogued in Mimics software and then individual fixation parameters were designed. Based on which percutaneous cannulated screws fixation of carpal scaphoid fracture were performed under Mimics individual fixation parameters. The accuracy of postoperation was assessed by CT scanning. Results There was no statistical difference in parameters of the CT scan and Mimics reconstruction images, which could reflect carpal scaphoid accurate three dimensional structure. Postoperation CT scanning showed that the cannulated screws were fixed successfully in 24 adult carpal scaphoid frac-tures. The function of wrists were well in follow-up. Conclusions Three-dimensional reconstruction of the carpal scaphoid by using mimics software, sham operated,measurement and design individual screw fixation parameters, can optimize operation schedule and method,decrease operation complication and risk, improve treatment effectiveness of clinical.