中国电机工程学报
中國電機工程學報
중국전궤공정학보
ZHONGGUO DIANJI GONGCHENG XUEBAO
2014年
33期
5941-5947
,共7页
康锦萍%徐英辉%刘晓芳%杨娅萍%罗应立
康錦萍%徐英輝%劉曉芳%楊婭萍%囉應立
강금평%서영휘%류효방%양아평%라응립
汽轮发电机%同步电抗%双因素%非线性%定子电感系数
汽輪髮電機%同步電抗%雙因素%非線性%定子電感繫數
기륜발전궤%동보전항%쌍인소%비선성%정자전감계수
turbine generator%synchronous reactances%two factors%nonlinear%stator winding inductances
汽轮发电机不同负载运行条件下的气隙电势与合成磁势的关系是与空载特性之间存在明显差异的一个曲线族。这种差异主要是由磁路饱和与磁场畸变双因素非线性共同作用引起的。该文以有限元方法为工具,研究不同功角时计及双因素非线性的定子绕组电感系数随转子角变化的特<br> 点,并比较分析其与不计饱和值之间的差异。提出一种通过寻求随转子角变化的定子电感矩阵的特征值来获取同步电抗的方法,该方法不仅能考虑双因素非线性和转子的运动,还能充分考虑定子电感系数的特点。用该方法计算的同步电抗都比制造厂给出的参数要小。计算定子电流的实例研究表明,用计及双因素非线性的同步电抗的计算结果与直接采用有限元方法的计算结果更接近。
汽輪髮電機不同負載運行條件下的氣隙電勢與閤成磁勢的關繫是與空載特性之間存在明顯差異的一箇麯線族。這種差異主要是由磁路飽和與磁場畸變雙因素非線性共同作用引起的。該文以有限元方法為工具,研究不同功角時計及雙因素非線性的定子繞組電感繫數隨轉子角變化的特<br> 點,併比較分析其與不計飽和值之間的差異。提齣一種通過尋求隨轉子角變化的定子電感矩陣的特徵值來穫取同步電抗的方法,該方法不僅能攷慮雙因素非線性和轉子的運動,還能充分攷慮定子電感繫數的特點。用該方法計算的同步電抗都比製造廠給齣的參數要小。計算定子電流的實例研究錶明,用計及雙因素非線性的同步電抗的計算結果與直接採用有限元方法的計算結果更接近。
기륜발전궤불동부재운행조건하적기극전세여합성자세적관계시여공재특성지간존재명현차이적일개곡선족。저충차이주요시유자로포화여자장기변쌍인소비선성공동작용인기적。해문이유한원방법위공구,연구불동공각시계급쌍인소비선성적정자요조전감계수수전자각변화적특<br> 점,병비교분석기여불계포화치지간적차이。제출일충통과심구수전자각변화적정자전감구진적특정치래획취동보전항적방법,해방법불부능고필쌍인소비선성화전자적운동,환능충분고필정자전감계수적특점。용해방법계산적동보전항도비제조엄급출적삼수요소。계산정자전류적실례연구표명,용계급쌍인소비선성적동보전항적계산결과여직접채용유한원방법적계산결과경접근。
The relationship between air-gap EMF and resultant MMF of turbine generators under different operating conditions is a series of curves which have the prominent difference from no-load characteristic. The difference is caused by interaction of two factors, i.e. iron saturation and magnetic field distortion nonlinearity. The features of stator inductances considering two factors varied with rotor angles are studied with the finite element method under different power angles. The difference between the calculated inductances and the unsaturated values is compared and analyzed. A method of calculating synchronous reactances is presented by solving characteristic values of stator inductances matrix value. The method can consider not only two factors and rotor movement but also features of the stator inductances. The calculated synchronous reactances are smaller than values given by factories. The case study of stator current calculation shows that the calculated results with synchronous reactances considering two factors are closer than the results using the finite element method.