中华现代护理杂志
中華現代護理雜誌
중화현대호리잡지
CHINESE JOURNAL OF MODERN NURSING
2014年
32期
4069-4071
,共3页
眼内压%角膜厚度%回弹式眼压计
眼內壓%角膜厚度%迴彈式眼壓計
안내압%각막후도%회탄식안압계
Intraocular pressures%Corneal thickness%ICare rebound tonometer
目的:探讨不同区域角膜厚度与ICare回弹式眼压计( RBT)测量的相关性。方法选择108例志愿者作为研究对象,应用光学相干断层扫描( OCT)测量角膜中央区域、距角膜缘2 mm的鼻侧及颞侧区域角膜厚度;用ICare回弹式眼压计测量相应角膜区域眼压值。采用Pearson相关分析,分析不同位置的角膜厚度与眼压的相关性。结果角膜中央、距角膜缘2 mm的鼻侧及颞侧区域角膜厚度分别为(527.84±32.93),(551.31±35.40),(533.91±34.42)μm,眼压分别为(16.39±5.31),(16.37±5.48),(16.44±5.72)mmHg;角膜厚度与眼压相关分析显示,角膜中心组(r=0.319,P<0.01)、鼻侧组(r=0.267,P<0.05)、颞侧组(r=0.299,P<0.02),角膜厚度与眼压具有相关性。结论不同区域角膜厚度会影响ICare回弹式眼压计测量眼压的结果。
目的:探討不同區域角膜厚度與ICare迴彈式眼壓計( RBT)測量的相關性。方法選擇108例誌願者作為研究對象,應用光學相榦斷層掃描( OCT)測量角膜中央區域、距角膜緣2 mm的鼻側及顳側區域角膜厚度;用ICare迴彈式眼壓計測量相應角膜區域眼壓值。採用Pearson相關分析,分析不同位置的角膜厚度與眼壓的相關性。結果角膜中央、距角膜緣2 mm的鼻側及顳側區域角膜厚度分彆為(527.84±32.93),(551.31±35.40),(533.91±34.42)μm,眼壓分彆為(16.39±5.31),(16.37±5.48),(16.44±5.72)mmHg;角膜厚度與眼壓相關分析顯示,角膜中心組(r=0.319,P<0.01)、鼻側組(r=0.267,P<0.05)、顳側組(r=0.299,P<0.02),角膜厚度與眼壓具有相關性。結論不同區域角膜厚度會影響ICare迴彈式眼壓計測量眼壓的結果。
목적:탐토불동구역각막후도여ICare회탄식안압계( RBT)측량적상관성。방법선택108례지원자작위연구대상,응용광학상간단층소묘( OCT)측량각막중앙구역、거각막연2 mm적비측급섭측구역각막후도;용ICare회탄식안압계측량상응각막구역안압치。채용Pearson상관분석,분석불동위치적각막후도여안압적상관성。결과각막중앙、거각막연2 mm적비측급섭측구역각막후도분별위(527.84±32.93),(551.31±35.40),(533.91±34.42)μm,안압분별위(16.39±5.31),(16.37±5.48),(16.44±5.72)mmHg;각막후도여안압상관분석현시,각막중심조(r=0.319,P<0.01)、비측조(r=0.267,P<0.05)、섭측조(r=0.299,P<0.02),각막후도여안압구유상관성。결론불동구역각막후도회영향ICare회탄식안압계측량안압적결과。
Objective To analyze and discuss the correlations between different areas of corneal thickness and ICare rebound tonometer ( RBT ) .Methods Totals of 108 volunteers were selected as the subjects.Corneal thicknesses (central cornea, 2mm distance of corneal limbus nasal side and temporal side,) were measured by using optical coherence tomography ( OCT) , and intraocular pressure of different corneal areas were measured with RBT.The correlation of corneal thickness and intraocular pressure in different corneal zones were analyzed by Pearson correlation analysis.Results Thicknesses in central cornea,2 mm distance of corneal limbus nasal side and temporal side were (527.84 ±32.93), (551.31 ±35.40) and (533.91 ±34.42)μm, respectively.Numbers of IOP were (16.39 ±5.31), (16.37 ±5.48) and (16.44 ±5.72) mmHg, respectively.Central corneal (r=0.319,P<0.01), nasal side (r=0.267,P<0.05),temporal side (r=0.299, P <0.02 ), positive correlation was found between corneal thickness and intraocular pressure. Conclusions Corneal thickness of different areas will affect measurement results of intraocular pressures by using ICare rebound tonometer.