目的:探讨低剂量对比剂联合生理盐水在标准体重患者宝石CT 肺动脉血管成像中的可行性。方法:40例标准体重(体重指数18.5~24.0!/")患者行CT肺动脉血管成像(CTPA),采用随机数字表达法根据对比剂使用剂量将患者分成两组:低剂量组,15 mL对比剂+50 mL混合液(10%对比剂+90%生理盐水);对照组,50 mL对比剂+30 mL生理盐水。由两名有经验的放射科医师分别独立对图像质量进行分析。结果:两名医师对两组肺动脉评分间的差异均无统计学意义(P>0.05);两组双肺下叶后基底段肺动脉的评分差异均无统计学意义(P>0.05);两组腔静脉的伪影评分差异均有统计学意义(P值均<0.05)。两组肺动脉主干与左心房、双肺下叶后基底段肺动脉与静脉CT 值的差值差异均无统计学意义(P>0.05)。结论:标准体重患者宝石CT肺动脉血管成像采用低剂量对比剂联合生理盐水可获得良好的图像,可以满足临床诊断。
目的:探討低劑量對比劑聯閤生理鹽水在標準體重患者寶石CT 肺動脈血管成像中的可行性。方法:40例標準體重(體重指數18.5~24.0!/")患者行CT肺動脈血管成像(CTPA),採用隨機數字錶達法根據對比劑使用劑量將患者分成兩組:低劑量組,15 mL對比劑+50 mL混閤液(10%對比劑+90%生理鹽水);對照組,50 mL對比劑+30 mL生理鹽水。由兩名有經驗的放射科醫師分彆獨立對圖像質量進行分析。結果:兩名醫師對兩組肺動脈評分間的差異均無統計學意義(P>0.05);兩組雙肺下葉後基底段肺動脈的評分差異均無統計學意義(P>0.05);兩組腔靜脈的偽影評分差異均有統計學意義(P值均<0.05)。兩組肺動脈主榦與左心房、雙肺下葉後基底段肺動脈與靜脈CT 值的差值差異均無統計學意義(P>0.05)。結論:標準體重患者寶石CT肺動脈血管成像採用低劑量對比劑聯閤生理鹽水可穫得良好的圖像,可以滿足臨床診斷。
목적:탐토저제량대비제연합생리염수재표준체중환자보석CT 폐동맥혈관성상중적가행성。방법:40례표준체중(체중지수18.5~24.0!/")환자행CT폐동맥혈관성상(CTPA),채용수궤수자표체법근거대비제사용제량장환자분성량조:저제량조,15 mL대비제+50 mL혼합액(10%대비제+90%생리염수);대조조,50 mL대비제+30 mL생리염수。유량명유경험적방사과의사분별독립대도상질량진행분석。결과:량명의사대량조폐동맥평분간적차이균무통계학의의(P>0.05);량조쌍폐하협후기저단폐동맥적평분차이균무통계학의의(P>0.05);량조강정맥적위영평분차이균유통계학의의(P치균<0.05)。량조폐동맥주간여좌심방、쌍폐하협후기저단폐동맥여정맥CT 치적차치차이균무통계학의의(P>0.05)。결론:표준체중환자보석CT폐동맥혈관성상채용저제량대비제연합생리염수가획득량호적도상,가이만족림상진단。
Objective:To discuss the feasibility of the reduced contrast dose with saline flushing in pulmonary CT an-giography of patients with standard weight with gemstone CT.Methods:According to the contrast dose,40 patients with standard body weight (BWI 18.5~24.0 !/")undergoing computed tomography pulmonary angiography (CTPA)were randomly divided into 2 groups:reduced contrast was treated with 15mL contrast and 50mL mixed solution (10% contrast and 90% saline)flushing,control group was treated 50mL contrast and 30mL saline flushing.The images were evaluated and analyzed by two experienced radiologists independently.Results:With rank sum test,the grading scores on the manifes-tation of the pulmonary artery and the posterior basal segmental pulmonary artery from the two radiologist were not signifi-cantly different between the two groups (P>0.05).The grading scores on the manifestation of the vena cava from the two radiologists were significantly different between the two groups (P<0.05).The differences of CT value between main pul-monary artery and left artium,the posterior basal segmental pulmonary artery and vein from the two radiologists between the two groups were not significantly different (P>0.05).Conclusion:The good image quality is obtained with the reduced contrast dose with saline flushing in pulmonary CT angiography of patients with standard body weight with gemstone CT and is satisfied for clinical diagnosis.