国际医药卫生导报
國際醫藥衛生導報
국제의약위생도보
INTERNATIONAL MEDICINE & HEALTH GUIDANCE NEWS
2014年
13期
1851-1853
,共3页
贾杰%李屹%胡祖荣%黎昆伟%黄希照%陈祥楠
賈傑%李屹%鬍祖榮%黎昆偉%黃希照%陳祥楠
가걸%리흘%호조영%려곤위%황희조%진상남
连续硬膜外阻滞%硬膜外导管%麻醉效果%剖宫产
連續硬膜外阻滯%硬膜外導管%痳醉效果%剖宮產
련속경막외조체%경막외도관%마취효과%부궁산
Consecutive epidural anesthesia%Epidural tube%Anesthetic effect%Cesarean section
目的 在剖宫产手术中,比较加强型聚脲胺酯钢丝硬外导管与聚氯乙烯硬膜外导管对硬膜外阻滞麻醉效果的影响.方法 200例拟行剖宫产手术产妇,采用连续硬膜外阻滞麻醉,随机分为聚氯乙烯硬膜外导管组(A组,n=100)和加强型聚脲胺酯钢丝硬膜外导管组(B组,n=100),以阻力消失作为判断硬膜外穿刺针顺利到达硬膜外腔的标志,记录放置硬膜外导管时遇到的阻力、触电感发生情况及阻滞平面达T6的局麻药剂量,并评价麻醉效果.结果 两组产妇人口学特征及手术时间等比较差异无统计学意义(P>0.05),A组和B组未遇到明显阻力分别为47.0%和91.0%,遇到轻微阻力分别为40.0%和8.0%;遇到阻力较大,放入导管困难分别为13.0%和1.0%,组间比较差异有统计学意义(P<0.01).A组触电感发生率为10.0%,B组触电感发生率为1.0%,组间比较差异有统计学意义(P<0.01);所需罗哌卡因剂量A组(133.0±26.0) mg、B组(121.0±7.0) mg,组间比较差异有统计学意义(P<0.05);麻醉效果评分A组(1.45±0.43)分、B组为(0.47±0.14)分,两组比较差异有统计学意义(P<0.05).结论 加强型聚脲胺酯钢丝硬膜外导管应用于剖宫产手术硬膜外腔麻醉中,硬外置管顺利,可明显改善麻醉效果.
目的 在剖宮產手術中,比較加彊型聚脲胺酯鋼絲硬外導管與聚氯乙烯硬膜外導管對硬膜外阻滯痳醉效果的影響.方法 200例擬行剖宮產手術產婦,採用連續硬膜外阻滯痳醉,隨機分為聚氯乙烯硬膜外導管組(A組,n=100)和加彊型聚脲胺酯鋼絲硬膜外導管組(B組,n=100),以阻力消失作為判斷硬膜外穿刺針順利到達硬膜外腔的標誌,記錄放置硬膜外導管時遇到的阻力、觸電感髮生情況及阻滯平麵達T6的跼痳藥劑量,併評價痳醉效果.結果 兩組產婦人口學特徵及手術時間等比較差異無統計學意義(P>0.05),A組和B組未遇到明顯阻力分彆為47.0%和91.0%,遇到輕微阻力分彆為40.0%和8.0%;遇到阻力較大,放入導管睏難分彆為13.0%和1.0%,組間比較差異有統計學意義(P<0.01).A組觸電感髮生率為10.0%,B組觸電感髮生率為1.0%,組間比較差異有統計學意義(P<0.01);所需囉哌卡因劑量A組(133.0±26.0) mg、B組(121.0±7.0) mg,組間比較差異有統計學意義(P<0.05);痳醉效果評分A組(1.45±0.43)分、B組為(0.47±0.14)分,兩組比較差異有統計學意義(P<0.05).結論 加彊型聚脲胺酯鋼絲硬膜外導管應用于剖宮產手術硬膜外腔痳醉中,硬外置管順利,可明顯改善痳醉效果.
목적 재부궁산수술중,비교가강형취뇨알지강사경외도관여취록을희경막외도관대경막외조체마취효과적영향.방법 200례의행부궁산수술산부,채용련속경막외조체마취,수궤분위취록을희경막외도관조(A조,n=100)화가강형취뇨알지강사경막외도관조(B조,n=100),이조력소실작위판단경막외천자침순리도체경막외강적표지,기록방치경막외도관시우도적조력、촉전감발생정황급조체평면체T6적국마약제량,병평개마취효과.결과 량조산부인구학특정급수술시간등비교차이무통계학의의(P>0.05),A조화B조미우도명현조력분별위47.0%화91.0%,우도경미조력분별위40.0%화8.0%;우도조력교대,방입도관곤난분별위13.0%화1.0%,조간비교차이유통계학의의(P<0.01).A조촉전감발생솔위10.0%,B조촉전감발생솔위1.0%,조간비교차이유통계학의의(P<0.01);소수라고잡인제량A조(133.0±26.0) mg、B조(121.0±7.0) mg,조간비교차이유통계학의의(P<0.05);마취효과평분A조(1.45±0.43)분、B조위(0.47±0.14)분,량조비교차이유통계학의의(P<0.05).결론 가강형취뇨알지강사경막외도관응용우부궁산수술경막외강마취중,경외치관순리,가명현개선마취효과.
Objective To compare the influence of wire polyurethane epidural tube with polyvinyl chloride epidural tube on the spinal anesthesia effect in cesarean section.Methods 200 pregnant women for elective cesarean section under epidural anesthesia were selected and randomly divided into two groups:polyvinyl chloride tube group (group A,n=100) and wire polyurethane epidural tube group (group B,n=100),the effects were judged by the epidural puncture needle getting to the epidural space without any resistance.In this process,the resistance to insertion of epidural tube,the incidence of electric shock and anesthesia dose on the block level were recorded,then we compared and evaluate the efficacy of the anesthesia.Results Demographic characteristics and time of operation of two groups had no statistical significance (P > 0.05).No resistance to insertion of epidural tube occurred in group A (47.0%) and 91.0% in group B of patients; Slight resistance was 40.0% in group A and 8.0% in group B; mild resistance and difficulty to insertion of epidural tube was encountered 13.0% and 1.0% of patients in group A and group B respectively.They were all significantly different (P < 0.01).The incidence of electrical sensation was 10.0% and 1.0% in group B,the difference had statistical significance (P < 0.01).The patients in group A who needed ropivacaine dose of (133.0 ± 26.0)mg,group B was (121.0 ± 7.0) mg,the difference had statistical significance (P < 0.05).Anesthesia effect score in group A was (1.45 ± 0.43),that of group B was (0.47 ± 0.14),the difference had statistical significance (P < 0.05).Conclusion Wire polyurethane epidural tube applied to spinal anesthesia in cesarean section has distinct effect than others,when it' s placed in epidural space more smoothly.