目的 建立华支睾吸虫IgG抗体检测试剂用血清国家参考品. 方法 2010-2012年,在广州进行华支睾吸虫病患者的粪检筛查,收集虫卵阳性者的血清26份.购买健康献血者血浆15份,每份200 ml.采用国内仅有的正在注册的2个华支睾吸虫IgG抗体检测试剂盒进行筛选和评价,确定参考品的组成,并进行分装精度测定和水分测定.选择3个单位对该参考品进行协作标定,检测血清参考品的阳性参考品符合率、阴性参考品符合率、最低检出量. 结果 华支睾吸虫IgG抗体检测试剂用血清国家参考品包括9份阳性参考品,10份阴性参考品,1份最低检出量参考品和1份精密性参考品.2次分装精度分别为0.6%和0.7%.2次水分检测结果均为2.8%.血清参考品的阳性参考品符合率、阴性参考品符合率均为100%,最低检出量均不高于1∶32. 结论 建立了华支睾吸虫IgG抗体检测试剂用血清国家参考品.
目的 建立華支睪吸蟲IgG抗體檢測試劑用血清國傢參攷品. 方法 2010-2012年,在廣州進行華支睪吸蟲病患者的糞檢篩查,收集蟲卵暘性者的血清26份.購買健康獻血者血漿15份,每份200 ml.採用國內僅有的正在註冊的2箇華支睪吸蟲IgG抗體檢測試劑盒進行篩選和評價,確定參攷品的組成,併進行分裝精度測定和水分測定.選擇3箇單位對該參攷品進行協作標定,檢測血清參攷品的暘性參攷品符閤率、陰性參攷品符閤率、最低檢齣量. 結果 華支睪吸蟲IgG抗體檢測試劑用血清國傢參攷品包括9份暘性參攷品,10份陰性參攷品,1份最低檢齣量參攷品和1份精密性參攷品.2次分裝精度分彆為0.6%和0.7%.2次水分檢測結果均為2.8%.血清參攷品的暘性參攷品符閤率、陰性參攷品符閤率均為100%,最低檢齣量均不高于1∶32. 結論 建立瞭華支睪吸蟲IgG抗體檢測試劑用血清國傢參攷品.
목적 건립화지고흡충IgG항체검측시제용혈청국가삼고품. 방법 2010-2012년,재엄주진행화지고흡충병환자적분검사사,수집충란양성자적혈청26빈.구매건강헌혈자혈장15빈,매빈200 ml.채용국내부유적정재주책적2개화지고흡충IgG항체검측시제합진행사선화평개,학정삼고품적조성,병진행분장정도측정화수분측정.선택3개단위대해삼고품진행협작표정,검측혈청삼고품적양성삼고품부합솔、음성삼고품부합솔、최저검출량. 결과 화지고흡충IgG항체검측시제용혈청국가삼고품포괄9빈양성삼고품,10빈음성삼고품,1빈최저검출량삼고품화1빈정밀성삼고품.2차분장정도분별위0.6%화0.7%.2차수분검측결과균위2.8%.혈청삼고품적양성삼고품부합솔、음성삼고품부합솔균위100%,최저검출량균불고우1∶32. 결론 건립료화지고흡충IgG항체검측시제용혈청국가삼고품.
Objective To establish a national reference for evaluation of detection reagent of antiClonorchis sinensis IgG.Methods A total of 26 serum samples of clonorchiasis patients confirmed by positive stool examination was collected in Guangzhou during 2010-2012,and 15 plasma samples of healthy blood donors were bought for each 200 ml.Samples were screened and evaluated with two domestic registered diagnostic kits for anti-Clonorchis sinensis.The composition of reference was determined,and sub-package accuracy and water content were detected.Three collaborative units were selected to calibrate and to detect the coincidence of positive reference and negative reference and the detection limit.Results The panel of Clonorchis sinensis IgG serum consisted of 9 positive and 10 negative samples,and one lowest detection sample,and one precision sample.Sub-package accuracy was 0.6% and 0.7%.Water content was 2.8%.The coincidence of both positive reference and negative reference was100%,and the detection limit was no more than 1:32.Conclusion The national reference panel of Anti-Clonorchis sinensis IgG serum was established.