目的 探讨准分子激光原位角膜磨镶术(LASIK)与准分子激光上皮下角膜切削术(LASEK)手术前后角膜前、后表面球差(C球)、彗差(C慧)、三叶草像差(C三)和总高阶像差(C高)的变化.方法 前瞻性病例对照研究.应用Oculyzer眼前节分析系统采集并计算LASIK组17例(34眼)、LASEK组17例(34眼)患者的角膜前后表面的各像差.对检查结果进行方差分析、独立样本t检验和Pearson相关分析.结果 LASIK组角膜前表面C球、C高在术后1个月和3个月时均较术前有明显增加,术后1个月和3个月时比较差异无统计学意义;LASEK组角膜前表面C球、C慧和C高在术后1个月和3个月时均较术前有明显增加,术后1个月和3个月时比较差异无统计学意义;术后1个月时LASIK组的角膜前表面C球和C高高于LASEK组,术后3个月仍呈现同样趋势,而角膜前表面C慧始终低于LASEK组,C三差异无统计学意义;术后LASIK组角膜前表面C球和C高的增高值(△C球、△C高)高于LASEK组,而C慧和C三的变化在两组之间差异无统计学意义;角膜前表面△C球和△C高与矫正的等效球镜度呈现显著的正相关关系;两种术式间、同种术式手术前后角膜后表面各像差值差异无统计学意义.结论 LASIK和LASEK术后角膜前表面的C球、C慧和C高会增大,且在术后3个月时尚无明显恢复;到术后3个月,角膜前表面△C球和△C高在LASIK组始终高于LASEK组,而这种变化与所矫正等效球镜度呈正相关;两种术式对角膜后表面的各像差均无影响.
目的 探討準分子激光原位角膜磨鑲術(LASIK)與準分子激光上皮下角膜切削術(LASEK)手術前後角膜前、後錶麵毬差(C毬)、彗差(C慧)、三葉草像差(C三)和總高階像差(C高)的變化.方法 前瞻性病例對照研究.應用Oculyzer眼前節分析繫統採集併計算LASIK組17例(34眼)、LASEK組17例(34眼)患者的角膜前後錶麵的各像差.對檢查結果進行方差分析、獨立樣本t檢驗和Pearson相關分析.結果 LASIK組角膜前錶麵C毬、C高在術後1箇月和3箇月時均較術前有明顯增加,術後1箇月和3箇月時比較差異無統計學意義;LASEK組角膜前錶麵C毬、C慧和C高在術後1箇月和3箇月時均較術前有明顯增加,術後1箇月和3箇月時比較差異無統計學意義;術後1箇月時LASIK組的角膜前錶麵C毬和C高高于LASEK組,術後3箇月仍呈現同樣趨勢,而角膜前錶麵C慧始終低于LASEK組,C三差異無統計學意義;術後LASIK組角膜前錶麵C毬和C高的增高值(△C毬、△C高)高于LASEK組,而C慧和C三的變化在兩組之間差異無統計學意義;角膜前錶麵△C毬和△C高與矯正的等效毬鏡度呈現顯著的正相關關繫;兩種術式間、同種術式手術前後角膜後錶麵各像差值差異無統計學意義.結論 LASIK和LASEK術後角膜前錶麵的C毬、C慧和C高會增大,且在術後3箇月時尚無明顯恢複;到術後3箇月,角膜前錶麵△C毬和△C高在LASIK組始終高于LASEK組,而這種變化與所矯正等效毬鏡度呈正相關;兩種術式對角膜後錶麵的各像差均無影響.
목적 탐토준분자격광원위각막마양술(LASIK)여준분자격광상피하각막절삭술(LASEK)수술전후각막전、후표면구차(C구)、혜차(C혜)、삼협초상차(C삼)화총고계상차(C고)적변화.방법 전첨성병례대조연구.응용Oculyzer안전절분석계통채집병계산LASIK조17례(34안)、LASEK조17례(34안)환자적각막전후표면적각상차.대검사결과진행방차분석、독립양본t검험화Pearson상관분석.결과 LASIK조각막전표면C구、C고재술후1개월화3개월시균교술전유명현증가,술후1개월화3개월시비교차이무통계학의의;LASEK조각막전표면C구、C혜화C고재술후1개월화3개월시균교술전유명현증가,술후1개월화3개월시비교차이무통계학의의;술후1개월시LASIK조적각막전표면C구화C고고우LASEK조,술후3개월잉정현동양추세,이각막전표면C혜시종저우LASEK조,C삼차이무통계학의의;술후LASIK조각막전표면C구화C고적증고치(△C구、△C고)고우LASEK조,이C혜화C삼적변화재량조지간차이무통계학의의;각막전표면△C구화△C고여교정적등효구경도정현현저적정상관관계;량충술식간、동충술식수술전후각막후표면각상차치차이무통계학의의.결론 LASIK화LASEK술후각막전표면적C구、C혜화C고회증대,차재술후3개월시상무명현회복;도술후3개월,각막전표면△C구화△C고재LASIK조시종고우LASEK조,이저충변화여소교정등효구경도정정상관;량충술식대각막후표면적각상차균무영향.
Objective To compare changes in wavefront aberrations on the anterior and posterior corneal surfaces after laser in situ keratomileusis (LASIK) and laser-assisted subepithelial keratectomy (LASEK) for myopia,especially for spherical aberrations,coma,trefoil and total higher order aberrations.Methods A prospective study was designed for 68 eyes of 34 patients who had undergone LASIK and LASEK.The patients were divided into 2 groups according to the procedure used.An oculyzer analytical system was used to measure corneal aberrations before and after surgery.Data were analyzed using ANOVA,independent samples t test and pearson correlation.Results One and 3 months after surgery,spherical aberrations and total higher-order aberrations of the anterior corneal surface in the LASIK group increased (P<0.01),but the differences at 1 month and 3 months were not significant (P>0.05).The same results occurred in the LASEK group for spherical aberrations,coma and total higher-order aberrations of the anterior corneal surface.Spherical aberrations and total higher-order aberrations of the anterior corneal surface were higher in the LASIK group than in the LASEK group 1 month after surgery (P<0.01),and the same tendency was found 3 months after surgery.However,coma aberrations on the anterior corneal surface in the LASIK group were less than those in the LASEK group at any time after surgery (P<0.05).No differences were found in trefoil aberrations on the anterior corneal surface during both procedures (P>0.05).Furthermore,the amount of correction achieved was positively correlated to these changes.Wavefront aberrations on the posterior corneal surface remained constant with both procedures and there were no differences when the procedures were compared (P>0.05).Conclusion Spherical aberrations,coma and total higher-order aberrations on the anterior corneal surface increased after both procedures,and did not recover until the 3 month after surgery.The changes in spherical aberrations and total higher-order aberrations on the anterior corneal surface were higher in the LASIK group than in the LASEK group,and depended on correction achieved in both procedures.The two procedures had no effect on wavefront aberrations on the posterior corneal surface.