目的 评价后房型有晶状体眼人工晶状体(ICL)植入术治疗高度近视术后1年的有效性和安全性.方法 回顾性病例研究.高度近视患者149例(290眼)接受ICL植入手术.其中男107眼,女183眼,平均年龄(29.0±6.5)岁.术前平均等效球镜度(-13.2±5.6)D.随诊时检查视力、眼压、屈光度和其他副作用.结果 所有眼睛的术后裸眼视力都有提高,接近术前最佳矫正视力.最后一次随访时199眼(68.6%)术后裸眼视力高于术前最佳矫正视力1行以上,无最佳矫正视力下降的病例.术后3 h内32眼眼压超过35 mmHg,其中13眼为瞳孔阻滞,19眼考虑为黏弹剂残留.术后随诊时发现3眼眼压在21~25 mmHg之间.2眼术后3个月以后发生黄斑区出血,3个月后出血吸收.3眼(2例)因为术后光晕干扰视物不适而取出ICL.12眼因为术后拱高欠佳而进行了人工晶状体置换术.结论 随诊1年显示ICL植入治疗高度近视是一种安全、有效而并发症少的治疗方法.
目的 評價後房型有晶狀體眼人工晶狀體(ICL)植入術治療高度近視術後1年的有效性和安全性.方法 迴顧性病例研究.高度近視患者149例(290眼)接受ICL植入手術.其中男107眼,女183眼,平均年齡(29.0±6.5)歲.術前平均等效毬鏡度(-13.2±5.6)D.隨診時檢查視力、眼壓、屈光度和其他副作用.結果 所有眼睛的術後裸眼視力都有提高,接近術前最佳矯正視力.最後一次隨訪時199眼(68.6%)術後裸眼視力高于術前最佳矯正視力1行以上,無最佳矯正視力下降的病例.術後3 h內32眼眼壓超過35 mmHg,其中13眼為瞳孔阻滯,19眼攷慮為黏彈劑殘留.術後隨診時髮現3眼眼壓在21~25 mmHg之間.2眼術後3箇月以後髮生黃斑區齣血,3箇月後齣血吸收.3眼(2例)因為術後光暈榦擾視物不適而取齣ICL.12眼因為術後拱高欠佳而進行瞭人工晶狀體置換術.結論 隨診1年顯示ICL植入治療高度近視是一種安全、有效而併髮癥少的治療方法.
목적 평개후방형유정상체안인공정상체(ICL)식입술치료고도근시술후1년적유효성화안전성.방법 회고성병례연구.고도근시환자149례(290안)접수ICL식입수술.기중남107안,녀183안,평균년령(29.0±6.5)세.술전평균등효구경도(-13.2±5.6)D.수진시검사시력、안압、굴광도화기타부작용.결과 소유안정적술후라안시력도유제고,접근술전최가교정시력.최후일차수방시199안(68.6%)술후라안시력고우술전최가교정시력1행이상,무최가교정시력하강적병례.술후3 h내32안안압초과35 mmHg,기중13안위동공조체,19안고필위점탄제잔류.술후수진시발현3안안압재21~25 mmHg지간.2안술후3개월이후발생황반구출혈,3개월후출혈흡수.3안(2례)인위술후광훈간우시물불괄이취출ICL.12안인위술후공고흠가이진행료인공정상체치환술.결론 수진1년현시ICL식입치료고도근시시일충안전、유효이병발증소적치료방법.
Objective To evaluate the efficacy,safety,and biocompatibility of a posterior chamber phakic intraocular lens (PCPIOL) to correct high myopia within 1 year.Methods In a retrospective case series study,an implantable intraocular lens was implanted in 290 eyes of 149 patients with a mean age of 29.0±6.5 years (range 20 to 49 years).There were 107 eyes from males and 183 eyes from females.Mean preoperative myopia was-13.2±5.6 D (range-6.0 to-32.0 D).The follow-up included tests for visual acuity,intraocular pressure,manifest refraction,and adverse reactions.Results Postoperatively,all eyes had a significant increase in uncorrected visual acuity (UCVA).Best corrected visual acuity (BCVA) had improved by 1 or more lines in 199 eyes (68.6%)at 1 year.No eye lost BCVA.Thirty-two eyes developed intraocular pressure (IOP) more than 35 mmHg within 3 hours after the implatation.Pupillary blockage caused an increase in IOP in 13 eyes and insufficient removal of viscoelastic material caused an increase in 19 eyes.IOP returned to normal in the following days after quick treatment.Three eyes had intraocular pressure between 21-25 mmHg.Two eyes had macular hemorrhage 3 months after the implantation,and the hemorrhage regressed 3 month later.Throe IOLs were removed from 2 patients because of an intolerant halo.The IOLs were exchanged in 12 eyes in 1 year because of high or low vault.Conclusion After 1 year of follow-up,IOL implantation had good visual and refractive results with excellent biocompatibility and fewer adverse reactions.