中华眼视光学与视觉科学杂志
中華眼視光學與視覺科學雜誌
중화안시광학여시각과학잡지
CHINESE JOURNAL OF OPTOMETRY OPHTHALMOLOGY AND VISUAL SCIENCE
2012年
12期
761-763
,共3页
张轶%邓应平%唐敏%黄晓旭%王琳%邱乐梅%孙成淑%张小兰
張軼%鄧應平%唐敏%黃曉旭%王琳%邱樂梅%孫成淑%張小蘭
장질%산응평%당민%황효욱%왕림%구악매%손성숙%장소란
角膜磨镶术,前弹力层下,激光%散光%负压吸引环,圆形%负压吸引环,椭圆形
角膜磨鑲術,前彈力層下,激光%散光%負壓吸引環,圓形%負壓吸引環,橢圓形
각막마양술,전탄력층하,격광%산광%부압흡인배,원형%부압흡인배,타원형
Keratomileusis,Sub-Bowman,lasers%Astigmatism%Vacuum aspiration rings,circular%Vacuum aspiration rings,oval
目的 探讨前弹力层下激光角膜磨镶术(SBK)手术中运用负压吸引圆环与椭圆环对患者术后角膜散光的影响.方法 回顾性病例对照研究.收集2011年3月在四川大学华西医院近视激光中心行SBK患者51例(102眼),在制作角膜瓣时,分别采用圆环和椭圆环,其中圆环组23例,椭圆环组25例,另外3例左右眼分别使用圆环与椭圆环,圆环眼纳入圆环组,椭圆环眼纳入椭圆环组.OrbscanⅡ角膜地形图检查患者术前、术后水平及垂直方向角膜曲率,并计算患者术前、术后散光值.采用独立样本t检验进行统计分析.结果 术后1周,圆环组角膜散光值为(-0.84±0.71)D,椭圆环组角膜散光值为(-0.90±0.54)D,两组之间差异无统计学意义.排除术中矫正散光值的影响,术前与术后1周角膜散光值差值椭圆环组为(0.58±0.77)D,圆环组为(0.57±0.76)D,两组差异无统计学意义.所有病例术中术后均未出现游离瓣、不全瓣、纽扣瓣等角膜瓣并发症,术后角膜愈合过程也未出现层间异物、瓣溶解、感染等严重影响视力的并发症.结论 相对传统负压吸引圆环来说,SBK手术中负压吸引椭圆环不会引起角膜散光值增加或降低.
目的 探討前彈力層下激光角膜磨鑲術(SBK)手術中運用負壓吸引圓環與橢圓環對患者術後角膜散光的影響.方法 迴顧性病例對照研究.收集2011年3月在四川大學華西醫院近視激光中心行SBK患者51例(102眼),在製作角膜瓣時,分彆採用圓環和橢圓環,其中圓環組23例,橢圓環組25例,另外3例左右眼分彆使用圓環與橢圓環,圓環眼納入圓環組,橢圓環眼納入橢圓環組.OrbscanⅡ角膜地形圖檢查患者術前、術後水平及垂直方嚮角膜麯率,併計算患者術前、術後散光值.採用獨立樣本t檢驗進行統計分析.結果 術後1週,圓環組角膜散光值為(-0.84±0.71)D,橢圓環組角膜散光值為(-0.90±0.54)D,兩組之間差異無統計學意義.排除術中矯正散光值的影響,術前與術後1週角膜散光值差值橢圓環組為(0.58±0.77)D,圓環組為(0.57±0.76)D,兩組差異無統計學意義.所有病例術中術後均未齣現遊離瓣、不全瓣、紐釦瓣等角膜瓣併髮癥,術後角膜愈閤過程也未齣現層間異物、瓣溶解、感染等嚴重影響視力的併髮癥.結論 相對傳統負壓吸引圓環來說,SBK手術中負壓吸引橢圓環不會引起角膜散光值增加或降低.
목적 탐토전탄력층하격광각막마양술(SBK)수술중운용부압흡인원배여타원배대환자술후각막산광적영향.방법 회고성병례대조연구.수집2011년3월재사천대학화서의원근시격광중심행SBK환자51례(102안),재제작각막판시,분별채용원배화타원배,기중원배조23례,타원배조25례,령외3례좌우안분별사용원배여타원배,원배안납입원배조,타원배안납입타원배조.OrbscanⅡ각막지형도검사환자술전、술후수평급수직방향각막곡솔,병계산환자술전、술후산광치.채용독립양본t검험진행통계분석.결과 술후1주,원배조각막산광치위(-0.84±0.71)D,타원배조각막산광치위(-0.90±0.54)D,량조지간차이무통계학의의.배제술중교정산광치적영향,술전여술후1주각막산광치차치타원배조위(0.58±0.77)D,원배조위(0.57±0.76)D,량조차이무통계학의의.소유병례술중술후균미출현유리판、불전판、뉴구판등각막판병발증,술후각막유합과정야미출현층간이물、판용해、감염등엄중영향시력적병발증.결론 상대전통부압흡인원배래설,SBK수술중부압흡인타원배불회인기각막산광치증가혹강저.
Objective To Compare the astigmatic results between circular vacuum aspiration rings and oval vacuum aspiration rings in Sub-Bowman's Keratomileusis (SBK).Methods It was a retrospective case controlled study.A total of 51 patients (102 eyes) who underwent SBK in the West China Hospital.Either circular vacuum aspiration rings or oval vacuum aspiration rings were chosen to make the corneal flaps.Circular vacuum aspiration rings were used in 49 eyes and oval vacuum aspiration rings were used in the other 53 eyes.Corneal curvature was measured with corneal topography and was used to calculate the astigmatic values.An independent samples t test was used.Results The astigmatic values 1 week after surgery for the oval vacuum aspiration ring group were -0.90±0.54 D and-0.84±0.71 D for the circular vacuum aspiration ring group.Astigmatic values change before 1 week after surgery in the oval vacuum aspiration ring group was 0.58±0.77 D and was 0.57±0.76 D in the circular vacuum aspiration ring group.There was no significant difference between the two groups.No complications were detected that would significantly affect visual acuity during or after surgery.Conclusion These results suggest that oval vacuum aspiration rings in SBK will not increase the induced astigmatism.