中华眼视光学与视觉科学杂志
中華眼視光學與視覺科學雜誌
중화안시광학여시각과학잡지
CHINESE JOURNAL OF OPTOMETRY OPHTHALMOLOGY AND VISUAL SCIENCE
2014年
4期
211-215
,共5页
缪华茂%何丽%李美燕%赵婧%孙玲%周行涛
繆華茂%何麗%李美燕%趙婧%孫玲%週行濤
무화무%하려%리미연%조청%손령%주행도
飞秒激光%角膜磨镶术,激光原位%视觉质量%眼内散射%近视
飛秒激光%角膜磨鑲術,激光原位%視覺質量%眼內散射%近視
비초격광%각막마양술,격광원위%시각질량%안내산사%근시
Femtosecond laser%Keratomileusis,laser in situ%Optical quality%Intraocular Scattering%Myopia
目的 探讨飞秒激光制瓣及板层角膜刀制瓣准分子激光原位角膜磨镶术后客观视觉质量及眼内散射.方法 回顾性研究.符合常规手术适应证,术前矫正视力≥5.0的近视患者72例(72眼).飞秒激光制瓣LASIK组(F-LASIK)35例(35眼),术前屈光度(-6.18±2.25)D;角膜刀制瓣LASIK组(M-LASIK)37例(37眼),术前屈光度(-6.62±1.78)D.术后1年应用客观视觉质量分析系统测量以下指标:调制传递函数截止频率(MTFcutoff),斯特列尔比以及眼内散射指数.2组间各参数比较应用独立极样t检验或Wilcoxon秩和检验.结果 2组术后均无最佳矫正视力丢失.安全指数F-LASIK组为1.06±0.12,M-LASIK组为1.05±0.14,2组差异无统计学意义(t=0.382,P>0.05);有效指数F-LASIK组为1.04±0.15,M-LASIK组为1.04±0.14,2组差异无统计学意义(t=0.156,P>0.05).F-LASIK组术后调制传递函数截止频率和斯特列尔比分别为(33.44±6.77) c/d和0.18±0.01,显著高于M-LASIK组[(29.14±9.08)c/d(t=2.264,P<0.05)和0.16±0.01(t=2.439,P<0.05)].F-LASIK组术后眼内散射指数为0.77±0.39,M-LASIK组为1.07±0.63,2组间差异无统计学意义(Z=-1.809,P>0.05).结论 F-LASIK术后可获得较好的客观视觉质量,调制传递函数截止频率和眼内散射的相关因素有待进一步探讨.
目的 探討飛秒激光製瓣及闆層角膜刀製瓣準分子激光原位角膜磨鑲術後客觀視覺質量及眼內散射.方法 迴顧性研究.符閤常規手術適應證,術前矯正視力≥5.0的近視患者72例(72眼).飛秒激光製瓣LASIK組(F-LASIK)35例(35眼),術前屈光度(-6.18±2.25)D;角膜刀製瓣LASIK組(M-LASIK)37例(37眼),術前屈光度(-6.62±1.78)D.術後1年應用客觀視覺質量分析繫統測量以下指標:調製傳遞函數截止頻率(MTFcutoff),斯特列爾比以及眼內散射指數.2組間各參數比較應用獨立極樣t檢驗或Wilcoxon秩和檢驗.結果 2組術後均無最佳矯正視力丟失.安全指數F-LASIK組為1.06±0.12,M-LASIK組為1.05±0.14,2組差異無統計學意義(t=0.382,P>0.05);有效指數F-LASIK組為1.04±0.15,M-LASIK組為1.04±0.14,2組差異無統計學意義(t=0.156,P>0.05).F-LASIK組術後調製傳遞函數截止頻率和斯特列爾比分彆為(33.44±6.77) c/d和0.18±0.01,顯著高于M-LASIK組[(29.14±9.08)c/d(t=2.264,P<0.05)和0.16±0.01(t=2.439,P<0.05)].F-LASIK組術後眼內散射指數為0.77±0.39,M-LASIK組為1.07±0.63,2組間差異無統計學意義(Z=-1.809,P>0.05).結論 F-LASIK術後可穫得較好的客觀視覺質量,調製傳遞函數截止頻率和眼內散射的相關因素有待進一步探討.
목적 탐토비초격광제판급판층각막도제판준분자격광원위각막마양술후객관시각질량급안내산사.방법 회고성연구.부합상규수술괄응증,술전교정시력≥5.0적근시환자72례(72안).비초격광제판LASIK조(F-LASIK)35례(35안),술전굴광도(-6.18±2.25)D;각막도제판LASIK조(M-LASIK)37례(37안),술전굴광도(-6.62±1.78)D.술후1년응용객관시각질량분석계통측량이하지표:조제전체함수절지빈솔(MTFcutoff),사특렬이비이급안내산사지수.2조간각삼수비교응용독립겁양t검험혹Wilcoxon질화검험.결과 2조술후균무최가교정시력주실.안전지수F-LASIK조위1.06±0.12,M-LASIK조위1.05±0.14,2조차이무통계학의의(t=0.382,P>0.05);유효지수F-LASIK조위1.04±0.15,M-LASIK조위1.04±0.14,2조차이무통계학의의(t=0.156,P>0.05).F-LASIK조술후조제전체함수절지빈솔화사특렬이비분별위(33.44±6.77) c/d화0.18±0.01,현저고우M-LASIK조[(29.14±9.08)c/d(t=2.264,P<0.05)화0.16±0.01(t=2.439,P<0.05)].F-LASIK조술후안내산사지수위0.77±0.39,M-LASIK조위1.07±0.63,2조간차이무통계학의의(Z=-1.809,P>0.05).결론 F-LASIK술후가획득교호적객관시각질량,조제전체함수절지빈솔화안내산사적상관인소유대진일보탐토.
Objective To investigate the objective optical quality and intraocular scatter after femtosecond laser and mechanical microkeratome LASIK for myopia correction.Methods This was a retrospective study.Seventy-two myopic eyes of 72 patients who conformed to the criteria for LASIK in preoperative examinations were enrolled.Patients had a best corrected visual acuity (BCVA) of ≥ 1.0.Thirty-five eyes of 35 patients were treated with LASIK with femtosecond laser flap preparation (F-LASIK),male∶female ratio=1∶1.3; 37 eyes of 37 patients were enrolled in the control group with microkeratome flap preparation (M-LASIK),male∶female ratio=l∶2.7.Optical quality parameters were measured in each patient 1 year after the LASIK surgeries:modulation transfer function cutoff frequency (MTFcutoff,cycles per degree,c/d),Strehl2D ratio (SR) and objective scatter index (OSI).Results Mean age was 26.71±5.89 years in the F-LASIK group and 28.67±6.62 years in the M-LASIK group;mean spherical equivalent refraction (SE) was-6.18±2.25 D in the F-LASIK group and-6.62±1.78 D in the M-LASIK group.Neither group had a reduction in BCVA.The safety index was 1.06±0.12 in the F-LASIK group and 1.05±0.14 in the M-LASIK group (t=0.382,P>0.05),while the efficacy index was 1.04±0.15 in the F-LASIK group and 1.04±0.14 in the M-LASIK group (t=0.156,P> 0.05).Mean postoperative MTFcutoff was 33.44±6.77 c/d after F-LASIK,which was significantly greater than the mean value of 29.14±9.08 c/d in the M-LASIK (t=2.264,P<0.05); mean SR was 0.18±0.01 in the F-LASIK,which was significantly greater than the mean value of 0.16±0.01 in the M-LASIK (t=2.439,P<0.05).Mean OSI was similar between the two groups,with 0.77±0.39 in the F-LASIK group and 1.07±0.63 in the the M-LASIK group (Z=-1.809,P>0.05).Conclusion Patients acquire better objective optical quality after femtosecond laser LASIK.However,further study is needed to investigate the factors associated with MTFcutoff and intraocular scatter.