角膜接触镜%视频终端%泪膜
角膜接觸鏡%視頻終耑%淚膜
각막접촉경%시빈종단%루막
Contact lens%Video display terminal%Tear film
目的 研究长时间注视视频终端(VDT)并且配戴角膜接触镜(CL)对泪膜功能的影响.方法 前瞻性病例对照研究.将研究对象分为三组:A组56例(112只眼),每日注视VDT≥5 h且配戴CL≥1年;B组45例(90只眼),每日注视VDT≥5 h,未配戴CL;C组39例(78只眼),每日注视VDT<2 h,配戴CL≥1年.观察三组人群SchirmerI试验(SIt),泪膜破裂时间(BUT),角膜荧光素(FL)染色,比较三组之间差异是否有统计学意义.结果 A组、B组、C组的BUT分别为(6.2±2.9)s、(7.2±4.0)s、(8.0±4.3)s,三组间差异有统计学意义(P=0.005),两两比较中,A组和B组,A组和C组之间差异有统计学意义,B组和C组之间差异无统计学意义.SIt和FL染色结果差异无统计学意义.结论 长时间注视VDT会损害泪膜功能,配戴CL加重注视VDT对泪膜功能的损害.
目的 研究長時間註視視頻終耑(VDT)併且配戴角膜接觸鏡(CL)對淚膜功能的影響.方法 前瞻性病例對照研究.將研究對象分為三組:A組56例(112隻眼),每日註視VDT≥5 h且配戴CL≥1年;B組45例(90隻眼),每日註視VDT≥5 h,未配戴CL;C組39例(78隻眼),每日註視VDT<2 h,配戴CL≥1年.觀察三組人群SchirmerI試驗(SIt),淚膜破裂時間(BUT),角膜熒光素(FL)染色,比較三組之間差異是否有統計學意義.結果 A組、B組、C組的BUT分彆為(6.2±2.9)s、(7.2±4.0)s、(8.0±4.3)s,三組間差異有統計學意義(P=0.005),兩兩比較中,A組和B組,A組和C組之間差異有統計學意義,B組和C組之間差異無統計學意義.SIt和FL染色結果差異無統計學意義.結論 長時間註視VDT會損害淚膜功能,配戴CL加重註視VDT對淚膜功能的損害.
목적 연구장시간주시시빈종단(VDT)병차배대각막접촉경(CL)대루막공능적영향.방법 전첨성병례대조연구.장연구대상분위삼조:A조56례(112지안),매일주시VDT≥5 h차배대CL≥1년;B조45례(90지안),매일주시VDT≥5 h,미배대CL;C조39례(78지안),매일주시VDT<2 h,배대CL≥1년.관찰삼조인군SchirmerI시험(SIt),루막파렬시간(BUT),각막형광소(FL)염색,비교삼조지간차이시부유통계학의의.결과 A조、B조、C조적BUT분별위(6.2±2.9)s、(7.2±4.0)s、(8.0±4.3)s,삼조간차이유통계학의의(P=0.005),량량비교중,A조화B조,A조화C조지간차이유통계학의의,B조화C조지간차이무통계학의의.SIt화FL염색결과차이무통계학의의.결론 장시간주시VDT회손해루막공능,배대CL가중주시VDT대루막공능적손해.
Objective To study the effects of contact lens wear on tear film function of visual display terminal (VDT) workers.Methods In this prospective case-control trial,a total of 140 patients (280 myopic eyes) were divided into three groups:group A (56 cases) that were engaged in VDT work no less than 5 hours a day and had wore contact lenses at least one year,group B (45 cases) that were engaged in VDT work no less than 5 hours a day and had never wore contact lenses,and group C (39 cases) that were engaged in VDT work less than 2 hours a day and had wore contact lenses at least 1 year.Schimer I test (SIt),tear break-up time (BUT) and fluorescein (FL) stain were measured among three groups.Results The BUT value was 6.2±2.9s in group 1,7.2±4.0s in group 2,8.0±4.3s in group 3 (P =0.005).The BUT value in group A was significantly lower than that in group B and group C,there were no significant differences between group B and group C.There were no significant differences in SIt and FL stain among three groups.Conclusions Long-term VDT work impairs the function of tear film.People who wear contact lenses suffer more changes on tear film function than those who never wear contact lenses when they are engaged in long-term VDT work.