中华实验外科杂志
中華實驗外科雜誌
중화실험외과잡지
CHINESE JOURNAL OF EXPERIMENTAL SURGERY
2013年
1期
129-131
,共3页
胡孔和%吴强%靳安民%段扬%席新华%赵卫东
鬍孔和%吳彊%靳安民%段颺%席新華%趙衛東
호공화%오강%근안민%단양%석신화%조위동
椎管扩大成形%内固定%生物力学
椎管擴大成形%內固定%生物力學
추관확대성형%내고정%생물역학
Expansive laminoplasty%Internal fixation%Biomechanics
目的 观察在单开门术中应用OsteoMed M3钉板内固定重建颈椎稳定性的效果.方法 6具新鲜颈椎标本,对每一标本先后行完整颈椎组、后路单开门OsteoMed M3钉板内固定组、后路椎板切除组、后路椎板切除加侧块钉棒内固定组的三维运动范围测试.结果 行后路钢板内固定组,在前屈(22.65±2.39)、后伸(15.63±1.56)、左侧弯(19.83±3.16)、右侧弯(16.90±2.13)及右旋(19.45±3.00)状态下运动范围与椎板切除组及侧块钉棒组之间的差异有统计学意义(P<0.05),与正常组的运动范围接近,差异无统计学意义(P>0.05);在左旋(20.67±2.89)状态下运动范围与其他各组之间的差异有统计学意义(P<0.05).椎板切除及侧块钉棒组与其他各组之间的差异有统计学意义(JP<0.05).结论 在单开门术中应用OsteoMed M3钉板内固定具有良好的生物力学性能,可重建颈椎稳定性.
目的 觀察在單開門術中應用OsteoMed M3釘闆內固定重建頸椎穩定性的效果.方法 6具新鮮頸椎標本,對每一標本先後行完整頸椎組、後路單開門OsteoMed M3釘闆內固定組、後路椎闆切除組、後路椎闆切除加側塊釘棒內固定組的三維運動範圍測試.結果 行後路鋼闆內固定組,在前屈(22.65±2.39)、後伸(15.63±1.56)、左側彎(19.83±3.16)、右側彎(16.90±2.13)及右鏇(19.45±3.00)狀態下運動範圍與椎闆切除組及側塊釘棒組之間的差異有統計學意義(P<0.05),與正常組的運動範圍接近,差異無統計學意義(P>0.05);在左鏇(20.67±2.89)狀態下運動範圍與其他各組之間的差異有統計學意義(P<0.05).椎闆切除及側塊釘棒組與其他各組之間的差異有統計學意義(JP<0.05).結論 在單開門術中應用OsteoMed M3釘闆內固定具有良好的生物力學性能,可重建頸椎穩定性.
목적 관찰재단개문술중응용OsteoMed M3정판내고정중건경추은정성적효과.방법 6구신선경추표본,대매일표본선후행완정경추조、후로단개문OsteoMed M3정판내고정조、후로추판절제조、후로추판절제가측괴정봉내고정조적삼유운동범위측시.결과 행후로강판내고정조,재전굴(22.65±2.39)、후신(15.63±1.56)、좌측만(19.83±3.16)、우측만(16.90±2.13)급우선(19.45±3.00)상태하운동범위여추판절제조급측괴정봉조지간적차이유통계학의의(P<0.05),여정상조적운동범위접근,차이무통계학의의(P>0.05);재좌선(20.67±2.89)상태하운동범위여기타각조지간적차이유통계학의의(P<0.05).추판절제급측괴정봉조여기타각조지간적차이유통계학의의(JP<0.05).결론 재단개문술중응용OsteoMed M3정판내고정구유량호적생물역학성능,가중건경추은정성.
Objective To investigate the stability of cervical vertebrae of the method for that OsteoMed M3 titanium plate and screws were used to secure the posterior elements in the open position after expansive unilateral open-door laminoplasty.Methods Six human cadaveric specimens were harvested freshly,and the range of motion of different groups was measured by a three-dimensional spinal stability test,including intact cervical specimens group,laminoplasty with plate group,laminectomy group,and laminectomy and fusion group.Results After expansive unilateral open-door laminoplasty,the plate group exhibited a more significant difference in angular motion than in laminectomy group,and laminectomy and fusion group in ROM of flexion (22.65 ± 2.39),extension (15.63 ± 1.56),left lateral bending (19.83 ±3.16),right lateral bending (16.90 ± 2.13) and right axial rotation (19.45 ± 3.00) (P < 0.05),and it was not significantly different from intact cervical specimens group (P > 0.05).The plate group exhibited a more significant difference in angular motion than other groups in ROM of left axial rotation (20.67 ±2.89) (P < 0.05).Laminectomy group,and laminectomy and fusion group exhibited a diference in angular motion in all directions (P < 0.05).Conclusion The biomechanical performance of expansive unilateral open-door laminoplasty with OsteoMed M3 plate and screws was excellent,and could remain initial stability of cervical vertebrae.