Maisonneuve骨折%胫腓联合%锁定钢板%生物力学
Maisonneuve骨摺%脛腓聯閤%鎖定鋼闆%生物力學
Maisonneuve골절%경비연합%쇄정강판%생물역학
Maisonneuve fracture%Syndesmosis%Locking plate%Biomechanical
目的 比较两孔锁定钢板固定下胫腓联合是否比传统螺钉固定更具生物力学优势.方法 选用12具防腐处理的小腿标本,模拟制造不稳定Maisonneuve骨折,随机分为两孔锁定钢板组和螺钉组.进行模拟步态的循环试验以及扭转失败的生物力学测试,测量下胫腓联合增宽、扭矩和角度.结果 两组内固定方法均能较好控制下胫腓联合增宽,钢板组稍占优势,但差异无统计学意义(0.07 mm比0.06 mm,P>0.05).钢板组和螺钉组的扭矩测量两组间差异有统计学意义,平均扭矩分别为40.48、20.17 Nm(P <0.05).结论两孔锁定钢板比两枚3.5mm四皮质螺钉固定下胫腓联合作用强.
目的 比較兩孔鎖定鋼闆固定下脛腓聯閤是否比傳統螺釘固定更具生物力學優勢.方法 選用12具防腐處理的小腿標本,模擬製造不穩定Maisonneuve骨摺,隨機分為兩孔鎖定鋼闆組和螺釘組.進行模擬步態的循環試驗以及扭轉失敗的生物力學測試,測量下脛腓聯閤增寬、扭矩和角度.結果 兩組內固定方法均能較好控製下脛腓聯閤增寬,鋼闆組稍佔優勢,但差異無統計學意義(0.07 mm比0.06 mm,P>0.05).鋼闆組和螺釘組的扭矩測量兩組間差異有統計學意義,平均扭矩分彆為40.48、20.17 Nm(P <0.05).結論兩孔鎖定鋼闆比兩枚3.5mm四皮質螺釘固定下脛腓聯閤作用彊.
목적 비교량공쇄정강판고정하경비연합시부비전통라정고정경구생물역학우세.방법 선용12구방부처리적소퇴표본,모의제조불은정Maisonneuve골절,수궤분위량공쇄정강판조화라정조.진행모의보태적순배시험이급뉴전실패적생물역학측시,측량하경비연합증관、뉴구화각도.결과 량조내고정방법균능교호공제하경비연합증관,강판조초점우세,단차이무통계학의의(0.07 mm비0.06 mm,P>0.05).강판조화라정조적뉴구측량량조간차이유통계학의의,평균뉴구분별위40.48、20.17 Nm(P <0.05).결론량공쇄정강판비량매3.5mm사피질라정고정하경비연합작용강.
Objective To determine whether a two-hole locking plate has biomechanical advantages over conventional screw stabilizsation of the syndesmosis in this injury pattern.Methods Six pairs of embalmed human cadaver lower legs were prepared to simulate an unstable Maisonneyve fracture.Each limb had randomly selected to receive either a 3.5 mm distal fibula locking plate with two 3.5 mm screws,or two parallel quadricortical 3.5 mm screws.The limbs were then mounted on a servo-hydraulic testing rig and axially loaded for 1200 cycles.Each limb was then externally rotated until failure occurred.Fibula diastasis,torque and angle were measured.Results Both constructs effectively stabilized the syndesmosis during the cyclical loading (0.07 mm vs.0.06 mm,P > 0.05).However the locking plate group demonstrated greater resistance to torque than quadricortical screw fixation (40.48 Nm vs.20.17 Nm,P<0.05).Conclusion A two-hole locking plate provides significantly greater stability of the syndesmosis to torque than 3.5 mm quadricortical fixation.