中华预防医学杂志
中華預防醫學雜誌
중화예방의학잡지
CHINESE JOURNAL OF
2013年
11期
1045-1049
,共5页
丁雄%聂凯%曾亚岚%王佶%石磊%马学军
丁雄%聶凱%曾亞嵐%王佶%石磊%馬學軍
정웅%섭개%증아람%왕길%석뢰%마학군
核酸扩增技术%HIV-1%萘酚类%恒温实时荧光
覈痠擴增技術%HIV-1%萘酚類%恆溫實時熒光
핵산확증기술%HIV-1%내분류%항온실시형광
Nucleic acid amplification tecniques%HIV-1%Naphthols%Isothermal real-time fluorescence assay
目的 基于逆转录环介导等温扩增(RT-LAMP)技术建立可用于现场检测HIV-1的方法.方法 构建实时荧光检测法时,先测试其特异性和灵敏度,并对其定量检测进行探索,然后用35份HIV-1阳性样本对该方法进行评定;在颜色判定法上,先对羟基萘酚蓝(HNB)进行改良,并验证其实际显色效果,然后选取效果明显的样本进行显色灵敏度测试和35份阳性样本显色评定.结果 实时荧光法对HIV-1有很好的检测特异性,灵敏度可达每反应管10 ~ 100拷贝数RNA.该方法对所有阳性临床样本均100% (35/35)检出,无一漏检,但其定量检测只局限于不低于每反应管103拷贝数.通过改良得到3种易分辨的HNB改良型显色剂,显色灵敏度等同于琼脂糖凝胶电泳级别,对35份HIV-1阳性样本的显色判定也无一漏检.结论 基于RT-LAMP技术的现场实时荧光法和改良型颜色判定法可以为真正实现现场快速、准确和灵敏检测HIV-1提供帮助.
目的 基于逆轉錄環介導等溫擴增(RT-LAMP)技術建立可用于現場檢測HIV-1的方法.方法 構建實時熒光檢測法時,先測試其特異性和靈敏度,併對其定量檢測進行探索,然後用35份HIV-1暘性樣本對該方法進行評定;在顏色判定法上,先對羥基萘酚藍(HNB)進行改良,併驗證其實際顯色效果,然後選取效果明顯的樣本進行顯色靈敏度測試和35份暘性樣本顯色評定.結果 實時熒光法對HIV-1有很好的檢測特異性,靈敏度可達每反應管10 ~ 100拷貝數RNA.該方法對所有暘性臨床樣本均100% (35/35)檢齣,無一漏檢,但其定量檢測隻跼限于不低于每反應管103拷貝數.通過改良得到3種易分辨的HNB改良型顯色劑,顯色靈敏度等同于瓊脂糖凝膠電泳級彆,對35份HIV-1暘性樣本的顯色判定也無一漏檢.結論 基于RT-LAMP技術的現場實時熒光法和改良型顏色判定法可以為真正實現現場快速、準確和靈敏檢測HIV-1提供幫助.
목적 기우역전록배개도등온확증(RT-LAMP)기술건립가용우현장검측HIV-1적방법.방법 구건실시형광검측법시,선측시기특이성화령민도,병대기정량검측진행탐색,연후용35빈HIV-1양성양본대해방법진행평정;재안색판정법상,선대간기내분람(HNB)진행개량,병험증기실제현색효과,연후선취효과명현적양본진행현색령민도측시화35빈양성양본현색평정.결과 실시형광법대HIV-1유흔호적검측특이성,령민도가체매반응관10 ~ 100고패수RNA.해방법대소유양성림상양본균100% (35/35)검출,무일루검,단기정량검측지국한우불저우매반응관103고패수.통과개량득도3충역분변적HNB개량형현색제,현색령민도등동우경지당응효전영급별,대35빈HIV-1양성양본적현색판정야무일루검.결론 기우RT-LAMP기술적현장실시형광법화개량형안색판정법가이위진정실현현장쾌속、준학화령민검측HIV-1제공방조.
Objective To establish the reverse transcription loop-mediated isothermal amplification (RT-LAMP) methods for on-site HIV-1 detection.Methods As for the real-time fluorescent RT-LAMP,we firstly tested the specificity and sensitivity,then explored its quantitative determination,and finally applied the method to the detection of 35 HIV-1 positive samples.For colorimetric judgment,after choosing different ameliorants to modify Hydroxynaphthol blue (HNB),we tested their real effects on coloration,and then picked out the modified dyes with obvious color change to test the sensitivity and the detection of the 35 HIV-1-positive samples.Results The real-time fluorescent RT-LAMP showed great specificity of HIV-1,and the sensitivity to detect HIV-1 RNA was between 10 and 100 copies per reaction.On testing 35 HIV-1-positive samples,the method could reach 100 percent detection rate.However,for the quantitative determination,the quantitative relation was not observed regarding the HIV-1 RNA of below 103 copies per reaction.Three modified HNB dyes with clear color variation between the reaction tubes of the negative and the positive were got in the study,and their sensitivities equaled to the level of agarose gel electrophoresis.Similarly,100% (35/35) detection rate was reached when the colorimetric RT-LAMP with the modified dyes was applied to detect 35 HIV-1-positive samples.Conclusion The established real-time fluorescence method and the modified color judgment of RT-LAMP could be helpful for truly achieving rapid,accurate,and sensitive on-site detection of HIV-1.