目的 探讨曲面断层测量法在分析下颌不对称畸形中的可行性.方法 选取25例主诉和外观皆无颜面部不对称的患者的曲面断层片(Pa)为对称组,16例颜面部不对称畸形患者的Pa和X线头颅后前位片(PAC)为不对称组.在两组的Pa影像上定位标志点,画出参考线和参考平面,确定相关测量项目.观察各定点位置的可重复性.比较对称组和不对称组的Pa左右两侧测量项目的差异,和两侧相应测量值的非对称率.对不对称组的Pa和PAC的相关测量项目的测量值进行相关性检验.结果 用参考线和参考平面辅助定位标志点的离散度<无辅助定位者,颏下点(Me)的离散度>颏孔点(MF).第1作者前后两次定点的可重复性与另5位测量者相似.对称组Pa大部分测量项目和不对称组Pa所有测量项目两侧测量值的差异皆有统计学意义(P<0.05).代表垂直向测量值的髁突点与下颌角点的距离(CP-GoP),两组平均相差4.73 mm(P<0.01);代表水平向测量值的下颌角点与颏孔点的距离(GoP-MF),两组平均相差5.77 mm(P<0.01).Pa与PAC水平向测量结果有较强的相关性(相关系数:0.78~0.85,P<0.01),垂直向测量结果相关性较差(相关系数:0.64,P<0.01).结论 参考线和参考平面辅助定位可提高Pa定点的可重复性,使定点更加明确;Pa影像颏孔点可用于曲面断层测量;曲面断层测量法可作为评价下颌是否不对称的方法.
目的 探討麯麵斷層測量法在分析下頜不對稱畸形中的可行性.方法 選取25例主訴和外觀皆無顏麵部不對稱的患者的麯麵斷層片(Pa)為對稱組,16例顏麵部不對稱畸形患者的Pa和X線頭顱後前位片(PAC)為不對稱組.在兩組的Pa影像上定位標誌點,畫齣參攷線和參攷平麵,確定相關測量項目.觀察各定點位置的可重複性.比較對稱組和不對稱組的Pa左右兩側測量項目的差異,和兩側相應測量值的非對稱率.對不對稱組的Pa和PAC的相關測量項目的測量值進行相關性檢驗.結果 用參攷線和參攷平麵輔助定位標誌點的離散度<無輔助定位者,頦下點(Me)的離散度>頦孔點(MF).第1作者前後兩次定點的可重複性與另5位測量者相似.對稱組Pa大部分測量項目和不對稱組Pa所有測量項目兩側測量值的差異皆有統計學意義(P<0.05).代錶垂直嚮測量值的髁突點與下頜角點的距離(CP-GoP),兩組平均相差4.73 mm(P<0.01);代錶水平嚮測量值的下頜角點與頦孔點的距離(GoP-MF),兩組平均相差5.77 mm(P<0.01).Pa與PAC水平嚮測量結果有較彊的相關性(相關繫數:0.78~0.85,P<0.01),垂直嚮測量結果相關性較差(相關繫數:0.64,P<0.01).結論 參攷線和參攷平麵輔助定位可提高Pa定點的可重複性,使定點更加明確;Pa影像頦孔點可用于麯麵斷層測量;麯麵斷層測量法可作為評價下頜是否不對稱的方法.
목적 탐토곡면단층측량법재분석하합불대칭기형중적가행성.방법 선취25례주소화외관개무안면부불대칭적환자적곡면단층편(Pa)위대칭조,16례안면부불대칭기형환자적Pa화X선두로후전위편(PAC)위불대칭조.재량조적Pa영상상정위표지점,화출삼고선화삼고평면,학정상관측량항목.관찰각정점위치적가중복성.비교대칭조화불대칭조적Pa좌우량측측량항목적차이,화량측상응측량치적비대칭솔.대불대칭조적Pa화PAC적상관측량항목적측량치진행상관성검험.결과 용삼고선화삼고평면보조정위표지점적리산도<무보조정위자,해하점(Me)적리산도>해공점(MF).제1작자전후량차정점적가중복성여령5위측량자상사.대칭조Pa대부분측량항목화불대칭조Pa소유측량항목량측측량치적차이개유통계학의의(P<0.05).대표수직향측량치적과돌점여하합각점적거리(CP-GoP),량조평균상차4.73 mm(P<0.01);대표수평향측량치적하합각점여해공점적거리(GoP-MF),량조평균상차5.77 mm(P<0.01).Pa여PAC수평향측량결과유교강적상관성(상관계수:0.78~0.85,P<0.01),수직향측량결과상관성교차(상관계수:0.64,P<0.01).결론 삼고선화삼고평면보조정위가제고Pa정점적가중복성,사정점경가명학;Pa영상해공점가용우곡면단층측량;곡면단층측량법가작위평개하합시부불대칭적방법.
Objective To evaluate the reliability of the panoramic radiographs for diagnosing mandibular asymmetry.Methods A total of 25 cases with no asymmetry in chief complaint or in appearance were selected for symmetry group.Pa and PAC from 16 cases of facial asymmetry were selected for asymmetric group.Marker points were fixed,a reference line and the reference plane drawn,and then relevant measurement items determined.The repeatability of the fixed position was observed.The difference of all measurement items between the left and right on Pa in symmetry group and asymmetric group were compared respectively and the asymmetric rate of corresponding measuredvalues on two sides between two groups were observed too.Correlation test was used to evaluate the measured-values on Pa and PAC in asymmetric group.Results Dispersion became smaller with the help of reference line and reference plane.And the dispersion was larger when Me was used as a marker other than MF.Most measured-values in symmetry group on Pa and all measured-values in asymmetric group on Pa showed statistically significant difference (P< 0.05).The mean difference of CP-GoP distance representing the vertical measured-value was 4.73 mm (P<0.01); and the mean difference of GoP-MF distance representing the horizontal measured-value was 5.77 mm (P<0.01).The horizontal measurements on PA and PAC showed closer correlation (r=0.78~0.85,P<0.01) while the vertical was poorer (r=0.64,P<0.01).Conclusions This study suggests that marking assisted with reference line and reference plane could get a more repeatable fixed-point on Pa.MF point could be used as a fixed-point for measuring mandibular asymmetry on Pa and the Pa measurement can be used to evaluate mandibular asymmetry.