目的 探讨在胸部肿瘤扫描中双源CT双能量方法虚拟平扫及双能量碘分布图技术的临床应用价值.方法 分析58例患者胸部肿瘤性病变的CT及临床资料.比较双能量组经处理得到的虚拟平扫与常规平扫相关指标,比较双能量组经处理得到的碘分布图强化CT值与常规组人工测量强化值对病灶良、恶性鉴别诊断的准确度.结果 虚拟平扫与常规平扫图像质量评分分别为(4.62±0.52)、(4.71±0.46)分(t=2.319,P> 0.05),图像噪声分别为(8.10±1.16)、(7.30±1.06) HU(t=5.246,P< 0.05),有效剂量分别为(5.18±0.96)、(5.55±1.18)mSv(t=4.005,P<0.05).碘分布图CT值与净强化CT值有良好相关性.结论 虚拟平扫图像对肺部病变显示良好,可满足诊断要求,有代替胸部常规平扫的潜在价值.双能量碘分布网反映血供的能力更直接、更敏感,可以定量表达病灶的强化程度,为临床肿瘤病变诊断提供更丰富的信息.
目的 探討在胸部腫瘤掃描中雙源CT雙能量方法虛擬平掃及雙能量碘分佈圖技術的臨床應用價值.方法 分析58例患者胸部腫瘤性病變的CT及臨床資料.比較雙能量組經處理得到的虛擬平掃與常規平掃相關指標,比較雙能量組經處理得到的碘分佈圖彊化CT值與常規組人工測量彊化值對病竈良、噁性鑒彆診斷的準確度.結果 虛擬平掃與常規平掃圖像質量評分分彆為(4.62±0.52)、(4.71±0.46)分(t=2.319,P> 0.05),圖像譟聲分彆為(8.10±1.16)、(7.30±1.06) HU(t=5.246,P< 0.05),有效劑量分彆為(5.18±0.96)、(5.55±1.18)mSv(t=4.005,P<0.05).碘分佈圖CT值與淨彊化CT值有良好相關性.結論 虛擬平掃圖像對肺部病變顯示良好,可滿足診斷要求,有代替胸部常規平掃的潛在價值.雙能量碘分佈網反映血供的能力更直接、更敏感,可以定量錶達病竈的彊化程度,為臨床腫瘤病變診斷提供更豐富的信息.
목적 탐토재흉부종류소묘중쌍원CT쌍능량방법허의평소급쌍능량전분포도기술적림상응용개치.방법 분석58례환자흉부종류성병변적CT급림상자료.비교쌍능량조경처리득도적허의평소여상규평소상관지표,비교쌍능량조경처리득도적전분포도강화CT치여상규조인공측량강화치대병조량、악성감별진단적준학도.결과 허의평소여상규평소도상질량평분분별위(4.62±0.52)、(4.71±0.46)분(t=2.319,P> 0.05),도상조성분별위(8.10±1.16)、(7.30±1.06) HU(t=5.246,P< 0.05),유효제량분별위(5.18±0.96)、(5.55±1.18)mSv(t=4.005,P<0.05).전분포도CT치여정강화CT치유량호상관성.결론 허의평소도상대폐부병변현시량호,가만족진단요구,유대체흉부상규평소적잠재개치.쌍능량전분포망반영혈공적능력경직접、경민감,가이정량표체병조적강화정도,위림상종류병변진단제공경봉부적신식.
Objective To investigate the clinical applications of dual-source dual-energy CT and dual-energy virtual unenhanced iodine distribution technology in thoracic tumor scans.Methods CT and clinical data of 58 cases of patients with thorax tumor were analyzed.The quality score,the noise,the average lesion CT values and radiation dose were compared between dual-energy group virtual unenhanced and conventional unenhanced image.The lesion benign and malignant differential diagnosis by strengthen the distribution of iodine value in dual-energy group and strengthen the value of manual measurement in conventional CT group were compared.Results The quality scores in virtual unenhanced and conventional unenhanced image were (4.62±0.52) and (4.71±0.46) points (t =2.319,P > 0.05).The noise in virtual unenhanced images and conventional unenhanced image were (8.10±1.16) and (7.30±1.06) HU (t =5.246,P< 0.05).The effective dose in virtual unenhanced and in conventional plain were (5.18±0.96) and (5.55±1.18) mSv (t =4.005,P < 0.05).CT value distribution of iodine was correlated with enhanced CT values.Conclusions The virtual unenhanced images can show well lung disease,which meet the diagnostic requirements and may be instead of the conventional plain chest potential value.Dual-energy iodine distribution of lesions can observe blood supply more directly and more sensitively,can quantityze expression of the extent of the lesions enhanced to provide richer information for clinical diagnosis of tumor lesions.