中华现代护理杂志
中華現代護理雜誌
중화현대호리잡지
CHINESE JOURNAL OF MODERN NURSING
2013年
7期
818-820
,共3页
谢拉%黄素芳%易艳%吴前胜
謝拉%黃素芳%易豔%吳前勝
사랍%황소방%역염%오전성
心肺复苏术%在职培训%个性化指导%新入职护士%反馈系统
心肺複囌術%在職培訓%箇性化指導%新入職護士%反饋繫統
심폐복소술%재직배훈%개성화지도%신입직호사%반궤계통
CPR%On-the-job training%Individualized guidance%New recruit nurse%Feedback system
目的 探讨个性化指导在新人职护士心肺复苏术(CPR)培训中的应用效果.方法 采用个性化指导对25名新护士进行CPR培训,培训前后分别在Laerdal ACLS高级生命支持模型人(200_05050)上进行CPR操作,并用Laerdal(R)计算机技能报告系统收集数据分析,比较培训前后操作情况.结果 个性化的指导培训后新护士胸外按压的各指标均有提高,按压深度足够率从65.2%提高至92.7%,不正确手部位置率从7.7%下降至1.3%,记录错误次数的比例从41.4%下降至17.6%,培训前后比较差异均有统计学意义(P<0.05);培训前后人工通气的潮气量比较,差异无统计学意义(Z=1.48,P>0.05).结论 个性化指导在新人职护士CPR培训中取得了很好的效果,可以在全院推广,并且合适的按压频率有待进一步探讨研究.
目的 探討箇性化指導在新人職護士心肺複囌術(CPR)培訓中的應用效果.方法 採用箇性化指導對25名新護士進行CPR培訓,培訓前後分彆在Laerdal ACLS高級生命支持模型人(200_05050)上進行CPR操作,併用Laerdal(R)計算機技能報告繫統收集數據分析,比較培訓前後操作情況.結果 箇性化的指導培訓後新護士胸外按壓的各指標均有提高,按壓深度足夠率從65.2%提高至92.7%,不正確手部位置率從7.7%下降至1.3%,記錄錯誤次數的比例從41.4%下降至17.6%,培訓前後比較差異均有統計學意義(P<0.05);培訓前後人工通氣的潮氣量比較,差異無統計學意義(Z=1.48,P>0.05).結論 箇性化指導在新人職護士CPR培訓中取得瞭很好的效果,可以在全院推廣,併且閤適的按壓頻率有待進一步探討研究.
목적 탐토개성화지도재신인직호사심폐복소술(CPR)배훈중적응용효과.방법 채용개성화지도대25명신호사진행CPR배훈,배훈전후분별재Laerdal ACLS고급생명지지모형인(200_05050)상진행CPR조작,병용Laerdal(R)계산궤기능보고계통수집수거분석,비교배훈전후조작정황.결과 개성화적지도배훈후신호사흉외안압적각지표균유제고,안압심도족구솔종65.2%제고지92.7%,불정학수부위치솔종7.7%하강지1.3%,기록착오차수적비례종41.4%하강지17.6%,배훈전후비교차이균유통계학의의(P<0.05);배훈전후인공통기적조기량비교,차이무통계학의의(Z=1.48,P>0.05).결론 개성화지도재신인직호사CPR배훈중취득료흔호적효과,가이재전원추엄,병차합괄적안압빈솔유대진일보탐토연구.
Objective To explore the personal guidance application effect of CPR training on new recruit nurses.Methods A total of 25 new nurses received CPR training by the personal guidance,and they were practiced on the Laerdal ACLS advanced life support model before and after the training,then compared the respective data collected by Laerdal computer skill report system.Results It revealed that significant difference in each indicator of chest compression,before and after the individualized guidance (P < 0.05),such as the incidence of displaying error after individualized guidance was 17.6% higher than before (41.4%) ; the incidence of chest compression that deeply enough was 92.7% higher than before (65.2%),and the proportion of incorrect hand position was 1.3%,which was lower than before (7.7%).No statistical difference in tidal volume of artificial ventilation,before and after the individualized guidance (P > 0.1).Conclusions The individualized guidance showed favorable results in new recruit nurses,which could be generalized in the clinical practice.Besides,the proper compression frequency requires further investigation.