目的 探讨角膜屈光手术中静态眼球旋转(SCC)和动态眼球旋转(DCC)的方向和程度.方法 回顾性病例研究.选择2013年5-7月接受个体化角膜屈光手术的患者144例(281眼),术中应用阿玛仕准分子激光仪(型号500)进行激光切削,测量并比较按性别、眼别、手术方式、术前等效球镜度分组后组间的SCC及DCC差异.计数资料采用卡方检验,计量资料采用成组设计t检验进行分析.结果 平均SCC为3.34°±2.57°(0°~12°).SCC成功率66.55%,飞秒LASIK手术(100例195眼)和Trans PRK手术(44例86眼)的SCC成功率分别为57.44%和87.21%,差异有统计学意义(x2=23.76,P<0.01).SCC成功的右眼中,60%发生逆时针旋转,SCC成功的左眼中,50%发生逆时针旋转.测得术中平均DCC幅度为2.30°±1.42°(0.00°~7.80°).接受飞秒LASIK手术的患眼,平均DCC幅度为2.05°±1.26°,接受Trans PRK手术的患眼为2.88°±1.59°,差异有统计学意义(t=4.33,P<0.01).术前等效球镜度≥-5.00 D的患眼,平均DCC幅度为2.51°±1.5l°,术前等效球镜度<-5.00 D的患眼为2.00°±1.23°,差异有统计学意义(t=3.07,P<0.01).结论 角膜屈光手术过程中,眼球会发生旋转.阿玛仕准分子激光仪能够准确有效地测量静态及动态眼球旋转,并进行补偿.
目的 探討角膜屈光手術中靜態眼毬鏇轉(SCC)和動態眼毬鏇轉(DCC)的方嚮和程度.方法 迴顧性病例研究.選擇2013年5-7月接受箇體化角膜屈光手術的患者144例(281眼),術中應用阿瑪仕準分子激光儀(型號500)進行激光切削,測量併比較按性彆、眼彆、手術方式、術前等效毬鏡度分組後組間的SCC及DCC差異.計數資料採用卡方檢驗,計量資料採用成組設計t檢驗進行分析.結果 平均SCC為3.34°±2.57°(0°~12°).SCC成功率66.55%,飛秒LASIK手術(100例195眼)和Trans PRK手術(44例86眼)的SCC成功率分彆為57.44%和87.21%,差異有統計學意義(x2=23.76,P<0.01).SCC成功的右眼中,60%髮生逆時針鏇轉,SCC成功的左眼中,50%髮生逆時針鏇轉.測得術中平均DCC幅度為2.30°±1.42°(0.00°~7.80°).接受飛秒LASIK手術的患眼,平均DCC幅度為2.05°±1.26°,接受Trans PRK手術的患眼為2.88°±1.59°,差異有統計學意義(t=4.33,P<0.01).術前等效毬鏡度≥-5.00 D的患眼,平均DCC幅度為2.51°±1.5l°,術前等效毬鏡度<-5.00 D的患眼為2.00°±1.23°,差異有統計學意義(t=3.07,P<0.01).結論 角膜屈光手術過程中,眼毬會髮生鏇轉.阿瑪仕準分子激光儀能夠準確有效地測量靜態及動態眼毬鏇轉,併進行補償.
목적 탐토각막굴광수술중정태안구선전(SCC)화동태안구선전(DCC)적방향화정도.방법 회고성병례연구.선택2013년5-7월접수개체화각막굴광수술적환자144례(281안),술중응용아마사준분자격광의(형호500)진행격광절삭,측량병비교안성별、안별、수술방식、술전등효구경도분조후조간적SCC급DCC차이.계수자료채용잡방검험,계량자료채용성조설계t검험진행분석.결과 평균SCC위3.34°±2.57°(0°~12°).SCC성공솔66.55%,비초LASIK수술(100례195안)화Trans PRK수술(44례86안)적SCC성공솔분별위57.44%화87.21%,차이유통계학의의(x2=23.76,P<0.01).SCC성공적우안중,60%발생역시침선전,SCC성공적좌안중,50%발생역시침선전.측득술중평균DCC폭도위2.30°±1.42°(0.00°~7.80°).접수비초LASIK수술적환안,평균DCC폭도위2.05°±1.26°,접수Trans PRK수술적환안위2.88°±1.59°,차이유통계학의의(t=4.33,P<0.01).술전등효구경도≥-5.00 D적환안,평균DCC폭도위2.51°±1.5l°,술전등효구경도<-5.00 D적환안위2.00°±1.23°,차이유통계학의의(t=3.07,P<0.01).결론 각막굴광수술과정중,안구회발생선전.아마사준분자격광의능구준학유효지측량정태급동태안구선전,병진행보상.
Objective To investigate the direction and the amount of static cyclotorsion (SCC) and dynamic cyclotorsion (DCC) in ametropic patients during corneal refractive surgery.Methods Two hundred eighty-one eyes of 144 patients who had undergone SCHWIND AMARIS corneal refractive surgery from May 2013 to July 2013 were involved in the study.Ablation was performed using the SCHWIND AMARIS (Version:500).The magnitudes of static and dynamic cyclotorsion were recorded in the supine position during the operation by the SCHWIND AMARIS excimer laser system.SCC and DCC were compared by gender,eye,surgical technique and preoperative spherical equivalent.Enumeration data were compared with a x2 test and measurement data with an intergroup t test.Results Prevalence rates were 66.55% for SCC,and the mean SCC value was 3.34°±2.57°(range 0° to 12°).Prevalence rates for Femto-LASIK and Trans PRK were 57.44% and 87.21%,respectively.The difference was statistically significant (x2=23.76,P<0.01).Sixty percent of the successful SCC right eyes and 50% of the successful SCC left eyes with counterclockwise rotation.The mean DCC amplitude was 2.30°±1.42°(0.00°~7.80°).The mean DCC amplitude was 2.05°±1.26°in eyes treated with Femto-LASIK and 2.88°±1.59° in eyes treated with Trans PRK.The difference was statistically significant (t=4.33,P<0.01).The mean DCC amplitude was 2.51°±1.51° in eyes with a preoperative spherical equivalent of ≥-5.00 D and 2.00°±1.23° in eyes with a preoperative spherical equivalent of <-5.00 D.The difference was statistically significant (t=3.07,P<0.01).Conclusion Significant cyclotorsion occurs during corneal refractive surgery.The SCHWIND AMARIS excimer laser system is a useful tool to measure static and dynamic cyclotorsion precisely and to compensate effectively.