目的 探讨超声血管增强技术(VET)在布-加综合征(BCS)支架置入术后疗效评估中的应用价值.方法 对39例BCS置入支架患者共41个支架进行二维超声、彩色多普勒及VET检查,存储支架及所在血管的静态及动态图像,比较血管内支架的二维与VET图像质量.对超声检查发现的支架狭窄的患者行数字减影血管造影(DSA)检查,测量支架内血栓范围,并与VET检查结果进行比较.结果 VET技术显示血管内支架图像质量评分高于二维超声,二者比较差异有统计学意义.VET显示的支架内血栓范围与DSA结果相近.结论 VET可改善血管内支架的清晰度,与彩色多普勒相结合,提高了超声在BCS支架置入术后疗效评估中的应用价值.
目的 探討超聲血管增彊技術(VET)在佈-加綜閤徵(BCS)支架置入術後療效評估中的應用價值.方法 對39例BCS置入支架患者共41箇支架進行二維超聲、綵色多普勒及VET檢查,存儲支架及所在血管的靜態及動態圖像,比較血管內支架的二維與VET圖像質量.對超聲檢查髮現的支架狹窄的患者行數字減影血管造影(DSA)檢查,測量支架內血栓範圍,併與VET檢查結果進行比較.結果 VET技術顯示血管內支架圖像質量評分高于二維超聲,二者比較差異有統計學意義.VET顯示的支架內血栓範圍與DSA結果相近.結論 VET可改善血管內支架的清晰度,與綵色多普勒相結閤,提高瞭超聲在BCS支架置入術後療效評估中的應用價值.
목적 탐토초성혈관증강기술(VET)재포-가종합정(BCS)지가치입술후료효평고중적응용개치.방법 대39례BCS치입지가환자공41개지가진행이유초성、채색다보륵급VET검사,존저지가급소재혈관적정태급동태도상,비교혈관내지가적이유여VET도상질량.대초성검사발현적지가협착적환자행수자감영혈관조영(DSA)검사,측량지가내혈전범위,병여VET검사결과진행비교.결과 VET기술현시혈관내지가도상질량평분고우이유초성,이자비교차이유통계학의의.VET현시적지가내혈전범위여DSA결과상근.결론 VET가개선혈관내지가적청석도,여채색다보륵상결합,제고료초성재BCS지가치입술후료효평고중적응용개치.
Objective To explore the value of vascular enhancement technology (VET) in the evaluation of therapeutic efficacy of stenting for Budd-Chiari syndrome (BCS).Methods Two-dimensional ultrasound,color Doppler and VET were performed on 39 BCS patients with 41 stents,the static and dynamic images of stents and vessels with stents were stored.VET and two-dimensional ultrasound imaging quality of intravascular stent were compared.Patients with stent stenosis found by ultrasound were examined by digital subtraction angiography(DSA).The ranges of stent thrombosis were measured by DSA and VET and the difference was compared.Results VET image quality scores of endovascular stent were higher than those of the two-dimensional ultrasound,the difference was statistically significant.The ranges of stent thrombosis measured by VET were similar to DSA.Conclusions VET can improve the clarity of intravascular stents.VET and color Doppler can enhance the clinical value of ultrasound in the evaluation of therapeutic efficacy of stenting for BCS.