中华超声影像学杂志
中華超聲影像學雜誌
중화초성영상학잡지
CHINESE JOURNAL OF ULTRASONOGRAPHY
2014年
6期
520-523
,共4页
陆林国%徐智章%刘吉斌%徐秋华%宋树良
陸林國%徐智章%劉吉斌%徐鞦華%宋樹良
륙림국%서지장%류길빈%서추화%송수량
超声检查%微气泡%外科皮瓣%穿支血管
超聲檢查%微氣泡%外科皮瓣%穿支血管
초성검사%미기포%외과피판%천지혈관
Ultrasonography%Microbubbles%Surgical flaps%Perforator vessels
目的 应用超声造影技术和三维重建技术检查腹壁下动脉穿支皮瓣(DIEP)血管,全面获取穿支血管的解剖信息,为临床提供更为准确的术前导航.方法 在常规超声基础上运用超声造影对43例乳房重建患者行DIEP穿支血管检查,并在超声造影状态下行三维重建.除定位穿支血管出肌点外,力求更清晰、直观地显示穿支的走行、与主干的关系以及穿支在皮瓣内的分支、分布情况.结果 超声造影清晰地显示和定位了40例(93%)DIEP穿支血管,并能明确其在肌层的走行、与主干的关系;对41例(95%)DIEP穿支进行重建图像获得较为满意的三维图像,可更全面直观地显示穿支血管的空间结构.所有病例均在术中证实超声所见,术后皮瓣均存活.结论 超声造影和三维重建技术能在常规超声基础上更全面、准确地定位和显示穿支血管,为DIEP穿支血管术前和术中发挥重要的导航作用.
目的 應用超聲造影技術和三維重建技術檢查腹壁下動脈穿支皮瓣(DIEP)血管,全麵穫取穿支血管的解剖信息,為臨床提供更為準確的術前導航.方法 在常規超聲基礎上運用超聲造影對43例乳房重建患者行DIEP穿支血管檢查,併在超聲造影狀態下行三維重建.除定位穿支血管齣肌點外,力求更清晰、直觀地顯示穿支的走行、與主榦的關繫以及穿支在皮瓣內的分支、分佈情況.結果 超聲造影清晰地顯示和定位瞭40例(93%)DIEP穿支血管,併能明確其在肌層的走行、與主榦的關繫;對41例(95%)DIEP穿支進行重建圖像穫得較為滿意的三維圖像,可更全麵直觀地顯示穿支血管的空間結構.所有病例均在術中證實超聲所見,術後皮瓣均存活.結論 超聲造影和三維重建技術能在常規超聲基礎上更全麵、準確地定位和顯示穿支血管,為DIEP穿支血管術前和術中髮揮重要的導航作用.
목적 응용초성조영기술화삼유중건기술검사복벽하동맥천지피판(DIEP)혈관,전면획취천지혈관적해부신식,위림상제공경위준학적술전도항.방법 재상규초성기출상운용초성조영대43례유방중건환자행DIEP천지혈관검사,병재초성조영상태하행삼유중건.제정위천지혈관출기점외,력구경청석、직관지현시천지적주행、여주간적관계이급천지재피판내적분지、분포정황.결과 초성조영청석지현시화정위료40례(93%)DIEP천지혈관,병능명학기재기층적주행、여주간적관계;대41례(95%)DIEP천지진행중건도상획득교위만의적삼유도상,가경전면직관지현시천지혈관적공간결구.소유병례균재술중증실초성소견,술후피판균존활.결론 초성조영화삼유중건기술능재상규초성기출상경전면、준학지정위화현시천지혈관,위DIEP천지혈관술전화술중발휘중요적도항작용.
Objective To assess the deep inferior epigastric perforator (DIEP) vessels in patients with breast reconstruction flaps by contrast-enhanced ultrasound (CEUS) and three-dimensional ultrasound (3DUS) reconstruction techniques.Methods Conventional ultrasound,CEUS and 3DUS were used to evaluate DIEP vessels of breast reconstruction flaps in 43 patients before surgical procedures.The identification,localization and spatial relationship of DIEP vessels were analyzed with conventional ultrasound,CEUS and 3DUS methods.The findings of CEUS and 3DUS were compared to conventional ultrasound and surgical outcome.Results Compared to CDFI,40 cases (93%) were observed more clearly with CEUS,and were showed more accurately than conventional ultrasound.41 cases (95%) could be displayed wonderfully in 3D ultrasound.Perforators which were detected by ultrasound were confirmed in the surgery and the transferred flaps survived completely.Conclusions Perforators can be displayed more clearly and located more accurately by CEUS and 3DUS.CEUS and 3DUS could play a very important role in the preoperative navigation of the DIEP than conventional ultrasound.