中华核医学与分子影像杂志
中華覈醫學與分子影像雜誌
중화핵의학여분자영상잡지
Chinese Journal of Nuclear Medicine and Molecular Imaging
2014年
1期
53-56
,共4页
蔡良%曾贵刚%陈曙光%张一秋%胡鹏程%李蓓蕾%张申%石洪成
蔡良%曾貴剛%陳曙光%張一鞦%鬍鵬程%李蓓蕾%張申%石洪成
채량%증귀강%진서광%장일추%호붕정%리배뢰%장신%석홍성
骨折,应力性%放射性核素显像%体层摄影术,发射型计算机,单光子%体层摄影术,X线计算机%MDP%兔
骨摺,應力性%放射性覈素顯像%體層攝影術,髮射型計算機,單光子%體層攝影術,X線計算機%MDP%兔
골절,응력성%방사성핵소현상%체층섭영술,발사형계산궤,단광자%체층섭영술,X선계산궤%MDP%토
Fractures,stress%Radionuclide imaging%Tomography,emission-computed,single-photon%Tomography,X-ray computed%MDP%Rabbits
目的 探讨99Tc皿-MDP骨平面显像结合SPECT/CT融合显像在应力性骨折(SF)早期诊断中的应用价值.方法 雄性新西兰大白兔12只,按照随机数字表法分为2组:实验组8只,进行跑跳训练6周;对照组4只,自由活动6周.全部兔均进行99Tcm-MDP骨平面显像和SPECT/CT融合显像.将胫骨均分为上、中、下3段,分别在平面图像和SPECT/CT融合图像上勾画各段ROI和三维ROI体积,并计算各自单位面积和体积的平均放射性计数.以对照组兔胫骨总的平均放射性计数为正常均值,计算可疑SF病变骨段放射性计数与正常均值的比值(SF/N),SF/N> 1.46为显像阳性.对显像结果与对应胫骨的病理诊断进行一致性Kappa检验.结果 12只兔共24根胫骨,骨平面显像半定量分析诊断SF的灵敏度、特异性及准确性分别为56.25%(9/16)、7/8和66.67% (16/24);骨平面显像结合SPECT/CT显像三维半定量分析诊断SF的相应指标分别为75.00%(12/16)、8/8和83.33% (20/24).后者的诊断准确性较前者明显提高.平面显像结合SPECT/CT显像的诊断结果与病理结果的Kappa值为0.667(P<0.05),两者一致性较好.结论 骨平面显像结合SPECT/CT显像诊断SF的灵敏度、特异性和准确性良好.
目的 探討99Tc皿-MDP骨平麵顯像結閤SPECT/CT融閤顯像在應力性骨摺(SF)早期診斷中的應用價值.方法 雄性新西蘭大白兔12隻,按照隨機數字錶法分為2組:實驗組8隻,進行跑跳訓練6週;對照組4隻,自由活動6週.全部兔均進行99Tcm-MDP骨平麵顯像和SPECT/CT融閤顯像.將脛骨均分為上、中、下3段,分彆在平麵圖像和SPECT/CT融閤圖像上勾畫各段ROI和三維ROI體積,併計算各自單位麵積和體積的平均放射性計數.以對照組兔脛骨總的平均放射性計數為正常均值,計算可疑SF病變骨段放射性計數與正常均值的比值(SF/N),SF/N> 1.46為顯像暘性.對顯像結果與對應脛骨的病理診斷進行一緻性Kappa檢驗.結果 12隻兔共24根脛骨,骨平麵顯像半定量分析診斷SF的靈敏度、特異性及準確性分彆為56.25%(9/16)、7/8和66.67% (16/24);骨平麵顯像結閤SPECT/CT顯像三維半定量分析診斷SF的相應指標分彆為75.00%(12/16)、8/8和83.33% (20/24).後者的診斷準確性較前者明顯提高.平麵顯像結閤SPECT/CT顯像的診斷結果與病理結果的Kappa值為0.667(P<0.05),兩者一緻性較好.結論 骨平麵顯像結閤SPECT/CT顯像診斷SF的靈敏度、特異性和準確性良好.
목적 탐토99Tc명-MDP골평면현상결합SPECT/CT융합현상재응력성골절(SF)조기진단중적응용개치.방법 웅성신서란대백토12지,안조수궤수자표법분위2조:실험조8지,진행포도훈련6주;대조조4지,자유활동6주.전부토균진행99Tcm-MDP골평면현상화SPECT/CT융합현상.장경골균분위상、중、하3단,분별재평면도상화SPECT/CT융합도상상구화각단ROI화삼유ROI체적,병계산각자단위면적화체적적평균방사성계수.이대조조토경골총적평균방사성계수위정상균치,계산가의SF병변골단방사성계수여정상균치적비치(SF/N),SF/N> 1.46위현상양성.대현상결과여대응경골적병리진단진행일치성Kappa검험.결과 12지토공24근경골,골평면현상반정량분석진단SF적령민도、특이성급준학성분별위56.25%(9/16)、7/8화66.67% (16/24);골평면현상결합SPECT/CT현상삼유반정량분석진단SF적상응지표분별위75.00%(12/16)、8/8화83.33% (20/24).후자적진단준학성교전자명현제고.평면현상결합SPECT/CT현상적진단결과여병리결과적Kappa치위0.667(P<0.05),량자일치성교호.결론 골평면현상결합SPECT/CT현상진단SF적령민도、특이성화준학성량호.
Objective To study the value of 99Tcm-MDP planar bone scintigraphy combined with SPECT/CT in the diagnosis of stress fracture (SF).Methods Twelve male New Zealand white rabbits were randomly divided into two groups by random number table method: 8 in the study group and 4 in the control group.The rabbits in the study group were given electronic stimulation regularly to let them jump in a special device for 6 weeks.All rabbits underwent both 99Tcm-MDP bone planar imaging and SPECT/CT.The tibia was divided into three parts (upper,middle and lower) and the corresponding ROI and volume of interest (VOI) were generated and mean radioactive counts were measured.The average radioactive counts of the control group served as the non-fracture reference.The radioactive counts ratio of suspected SF/nonfracture tibia (SF/N) was calculated.SF/N of 1.46 was the cut-off value for positive SF lesions.Finally,pathological examination was performed in each tibia of the rabbits.Kappa test was used to analyze the consistency between the imaging and histological findings.Results The sensitivity,specificity,accuracy for the diagnosis of SF was 56.25% (9/16),7/8,66.67% (16/24) by planar bone scintigraphy,and 75.00%(12/16),8/8,83.33% (20/24) by bone scintigraphy combined with SPECT/CT,respectively.The diagnosis by planar imaging combined with SPECT/CT was significantly more accurate than that of the planar imaging alone.The Kappa value between bone scintigraphy combined with SPECT/CT and pathological findings was 0.667 (P<0.05).Conclusion Planar imaging combined with SPECT/CT can improve the diagnostic efficacy of SF.