中华口腔医学杂志
中華口腔醫學雜誌
중화구강의학잡지
Chinese Journal of Stomatology
2012年
z1期
94-96
,共3页
毛钊%严晓东%唐成忠%郭红艳%罗会楠
毛釗%嚴曉東%唐成忠%郭紅豔%囉會楠
모쇠%엄효동%당성충%곽홍염%라회남
牙种植体%即刻种植%引导骨再生
牙種植體%即刻種植%引導骨再生
아충식체%즉각충식%인도골재생
Dental implants%Immediate implantation%Guided bone regeneration
目的 观察即刻种植修复缺失牙后软硬组织的临床变化情况.方法 10例患者的种植体20枚(直径为4.1或4.8 mm,长度10或12 mm),其中10枚为即刻种植,10枚为常规种植,在即刻植入的同时进行引导骨再生(guided bone regeneration,GBR)的骨增量手术.完成义齿修复后随访观察1年,通过X线片分别测量即刻种植和常规种植的硬组织变化量,进行对比分析.同时记录各组种植体的牙周探诊深度和龈乳头指数,分析即刻种植对牙周软组织有无影响.结果 1年后10例患者的种植体20枚均存留,患者主观全部满意.种植体周软硬组织无病理性异常.1年后硬组织平均吸收值常规种植组(1.76±0.21) mm,即刻种植组(1.80±0.15) mm,两者比较差异无统计学意义(P>0.05).对比1年后两组牙周探诊深度:即刻种植组(2.31 ±0.84)mm,常规种植组(2.27±0.84) mm,两组间差异无统计学意义(P>0.05).两组龈乳头指数的频数分布比较,差异无统计学意义(P>0.05).结论 即刻种植的近期种植体周软硬组织变化达到临床治疗要求.
目的 觀察即刻種植脩複缺失牙後軟硬組織的臨床變化情況.方法 10例患者的種植體20枚(直徑為4.1或4.8 mm,長度10或12 mm),其中10枚為即刻種植,10枚為常規種植,在即刻植入的同時進行引導骨再生(guided bone regeneration,GBR)的骨增量手術.完成義齒脩複後隨訪觀察1年,通過X線片分彆測量即刻種植和常規種植的硬組織變化量,進行對比分析.同時記錄各組種植體的牙週探診深度和齦乳頭指數,分析即刻種植對牙週軟組織有無影響.結果 1年後10例患者的種植體20枚均存留,患者主觀全部滿意.種植體週軟硬組織無病理性異常.1年後硬組織平均吸收值常規種植組(1.76±0.21) mm,即刻種植組(1.80±0.15) mm,兩者比較差異無統計學意義(P>0.05).對比1年後兩組牙週探診深度:即刻種植組(2.31 ±0.84)mm,常規種植組(2.27±0.84) mm,兩組間差異無統計學意義(P>0.05).兩組齦乳頭指數的頻數分佈比較,差異無統計學意義(P>0.05).結論 即刻種植的近期種植體週軟硬組織變化達到臨床治療要求.
목적 관찰즉각충식수복결실아후연경조직적림상변화정황.방법 10례환자적충식체20매(직경위4.1혹4.8 mm,장도10혹12 mm),기중10매위즉각충식,10매위상규충식,재즉각식입적동시진행인도골재생(guided bone regeneration,GBR)적골증량수술.완성의치수복후수방관찰1년,통과X선편분별측량즉각충식화상규충식적경조직변화량,진행대비분석.동시기록각조충식체적아주탐진심도화간유두지수,분석즉각충식대아주연조직유무영향.결과 1년후10례환자적충식체20매균존류,환자주관전부만의.충식체주연경조직무병이성이상.1년후경조직평균흡수치상규충식조(1.76±0.21) mm,즉각충식조(1.80±0.15) mm,량자비교차이무통계학의의(P>0.05).대비1년후량조아주탐진심도:즉각충식조(2.31 ±0.84)mm,상규충식조(2.27±0.84) mm,량조간차이무통계학의의(P>0.05).량조간유두지수적빈수분포비교,차이무통계학의의(P>0.05).결론 즉각충식적근기충식체주연경조직변화체도림상치료요구.
Objective To observe the change of hard tissue in dental immediate implantation.Methods Twenty implants were implanted in 10 patients including 10 implants of immediate implantation and 10 regular implantation.They were followed up for one year after functional loading.Hard and soft tissue changes were evaluated by measuring the mesial and distal bone lever on X-ray.Pocket probing depth and papilla index were assessed during 1 year follow up period.Results After one year of functional loading,the implant retention rate was 100%,the patient subjective satisfaction rate was 100%.Hard and soft tissues around implant showed no pathological abnormalities.The average absorption of hard tissue after 1 year in conventional group was (1.76 ±0.21) mm,and (1.80 ±0.15) mm in immediate implant group,which showed no statistically significant difference between the two groups.The pocket probing depth in immediate implantation group was (2.31 ± 0.84) mm and (2.27 ± 0.84)mm in conventional group (P >0.05).The frequency distributions of the scores of papilla index of both groups were not significantly different between the two groups.Conclusions The hard and soft tissue changes in immediate dental implantation were within the normal ranges.