目的 评价新型环氧树脂的聚合体积收缩率和聚合收缩应力,为其临床应用提供参考.方法 选用3种复合树脂材料:A组:丙烯酸酯树脂(XenoⅢ-TPH);B组:丙烯酸酯树脂(Clearfil SE bond-Clearfil Majesty Posterior);C组:新型环氧树脂(FiltekTM silorane adhesive-P90).3组复合树脂经光照固化后,用显微CT测量聚合体积收缩率,用万能材料实验机测试聚合收缩应力.结果 A、B和C组复合树脂的聚合体积收缩率分别为(3.38±0.17)%、(1.95±0.37)%和(1.05%±0.09)%;C组最小,与A、B组的差异均有统计学意义(P <0.001).A、B和C组复合树脂的聚合收缩应力分别为(3.04 ±0.26)、(3.49±0.46)和(1.54±0.15) MPa;C组最小,与A、B组的差异均有统计学意义(P<0.001).结论 新型环氧树脂具有优良的低聚合收缩性能.
目的 評價新型環氧樹脂的聚閤體積收縮率和聚閤收縮應力,為其臨床應用提供參攷.方法 選用3種複閤樹脂材料:A組:丙烯痠酯樹脂(XenoⅢ-TPH);B組:丙烯痠酯樹脂(Clearfil SE bond-Clearfil Majesty Posterior);C組:新型環氧樹脂(FiltekTM silorane adhesive-P90).3組複閤樹脂經光照固化後,用顯微CT測量聚閤體積收縮率,用萬能材料實驗機測試聚閤收縮應力.結果 A、B和C組複閤樹脂的聚閤體積收縮率分彆為(3.38±0.17)%、(1.95±0.37)%和(1.05%±0.09)%;C組最小,與A、B組的差異均有統計學意義(P <0.001).A、B和C組複閤樹脂的聚閤收縮應力分彆為(3.04 ±0.26)、(3.49±0.46)和(1.54±0.15) MPa;C組最小,與A、B組的差異均有統計學意義(P<0.001).結論 新型環氧樹脂具有優良的低聚閤收縮性能.
목적 평개신형배양수지적취합체적수축솔화취합수축응력,위기림상응용제공삼고.방법 선용3충복합수지재료:A조:병희산지수지(XenoⅢ-TPH);B조:병희산지수지(Clearfil SE bond-Clearfil Majesty Posterior);C조:신형배양수지(FiltekTM silorane adhesive-P90).3조복합수지경광조고화후,용현미CT측량취합체적수축솔,용만능재료실험궤측시취합수축응력.결과 A、B화C조복합수지적취합체적수축솔분별위(3.38±0.17)%、(1.95±0.37)%화(1.05%±0.09)%;C조최소,여A、B조적차이균유통계학의의(P <0.001).A、B화C조복합수지적취합수축응력분별위(3.04 ±0.26)、(3.49±0.46)화(1.54±0.15) MPa;C조최소,여A、B조적차이균유통계학의의(P<0.001).결론 신형배양수지구유우량적저취합수축성능.
Objective To determine whether a new dedicated adhesive system employing a silorane composite exhibits low shrinking properties than does conventional methacrylate-based composites.Methods The following materials were used:group A:Xeno Ⅲ-TPH,group B:Clearfil SE bond-Clearfil Majesty Posterior,and group C:the FiltekTM silorane system.Polymerization volumetric shrinkage and contraction stress development were measured using a micro-CT instrument and a tensilometer.Results The volumetric shrinkage of the resin composite/adhesive combinations were 3.38% ± 0.17% (group A),1.95% ± 0.37% (group B) and 1.05% ±0.09% (group C) 30 min after light curing respectively.Group C had the lowest volumetric shrinkage (P <0.001),followed by group B,and group A.The contraction stress of the materials were (3.04 ± 0.26) MPa(group A),(3.49 ± 0.46) MPa (group B),and (1.54 ± 0.15) MPa (group C) respectively.The lowest contraction stress was observed in group C at 30 min during the stress test (P < 0.001).Conclusions The silorane composite and dedicated adhesive system exhibited excellent characteristics of low volumetric shrinkage and contraction stress development compared to conventional methacrylate-based composites.