中华劳动卫生职业病杂志
中華勞動衛生職業病雜誌
중화노동위생직업병잡지
CHINESE JOURNAL OF INDUSTRIAL HYGIENE AND OCCUPATIONAL DISEASES
2013年
5期
351-355
,共5页
王晓华%刘东声%宣晓%康涵%袁慧书
王曉華%劉東聲%宣曉%康涵%袁慧書
왕효화%류동성%선효%강함%원혜서
粉尘%职业暴露%放射摄影术%X线
粉塵%職業暴露%放射攝影術%X線
분진%직업폭로%방사섭영술%X선
Dust%Occupational exposure%Radiolography%X-ray
目的 探讨不同数字化胸片(DR)处理参数对接尘者数字化X线胸片图像的影响.方法 对105例粉尘作业人员,同时拍摄高仟伏X线胸片和DR,用DR常规处理法和职业病特殊要求处理法设置不同的图像处理参数.参照高仟伏胸片分别对10个解剖部位的显示情况进行评分,比较DR常规处理法和职业病特殊要求处理法处理DR图像的差异,并与高仟伏胸片进行比较.结果 DR常规处理法处理DR图像10个解剖部位的评分大部分集中于0和+1水平,二者共占88%以上,评分均值在0.23~0.65之间,DR图像评分均值与高仟伏图像评分的差异有明显统计学意义(P<0.01);职业病特殊要求处理法处理DR图像10个解剖部位的评分大部分集中于0,可占65%以上.除“胸膜胸壁”外,评分均值在-0.01 ~+0.02之间,DR图像评分均值与高仟伏图像评分的差异无统计学意义(P>0.05).经DR常规处理法和职业病特殊要求处理法处理的DR图像的1 0个解剖部位评分的差异均有统计学意义(P<0.01).结论 不同处理参数得到的DR图像不同,经职业病特殊要求处理法处理的DR图像对解剖部位的显示基本等同于高仟伏胸片.
目的 探討不同數字化胸片(DR)處理參數對接塵者數字化X線胸片圖像的影響.方法 對105例粉塵作業人員,同時拍攝高仟伏X線胸片和DR,用DR常規處理法和職業病特殊要求處理法設置不同的圖像處理參數.參照高仟伏胸片分彆對10箇解剖部位的顯示情況進行評分,比較DR常規處理法和職業病特殊要求處理法處理DR圖像的差異,併與高仟伏胸片進行比較.結果 DR常規處理法處理DR圖像10箇解剖部位的評分大部分集中于0和+1水平,二者共佔88%以上,評分均值在0.23~0.65之間,DR圖像評分均值與高仟伏圖像評分的差異有明顯統計學意義(P<0.01);職業病特殊要求處理法處理DR圖像10箇解剖部位的評分大部分集中于0,可佔65%以上.除“胸膜胸壁”外,評分均值在-0.01 ~+0.02之間,DR圖像評分均值與高仟伏圖像評分的差異無統計學意義(P>0.05).經DR常規處理法和職業病特殊要求處理法處理的DR圖像的1 0箇解剖部位評分的差異均有統計學意義(P<0.01).結論 不同處理參數得到的DR圖像不同,經職業病特殊要求處理法處理的DR圖像對解剖部位的顯示基本等同于高仟伏胸片.
목적 탐토불동수자화흉편(DR)처리삼수대접진자수자화X선흉편도상적영향.방법 대105례분진작업인원,동시박섭고천복X선흉편화DR,용DR상규처리법화직업병특수요구처리법설치불동적도상처리삼수.삼조고천복흉편분별대10개해부부위적현시정황진행평분,비교DR상규처리법화직업병특수요구처리법처리DR도상적차이,병여고천복흉편진행비교.결과 DR상규처리법처리DR도상10개해부부위적평분대부분집중우0화+1수평,이자공점88%이상,평분균치재0.23~0.65지간,DR도상평분균치여고천복도상평분적차이유명현통계학의의(P<0.01);직업병특수요구처리법처리DR도상10개해부부위적평분대부분집중우0,가점65%이상.제“흉막흉벽”외,평분균치재-0.01 ~+0.02지간,DR도상평분균치여고천복도상평분적차이무통계학의의(P>0.05).경DR상규처리법화직업병특수요구처리법처리적DR도상적1 0개해부부위평분적차이균유통계학의의(P<0.01).결론 불동처리삼수득도적DR도상불동,경직업병특수요구처리법처리적DR도상대해부부위적현시기본등동우고천복흉편.
Objective To investigate the effect of different processing parameters of digital radiography (DR) on the image quality of digital chest radiograph in dust-exposed workers.Methods One hundred and five dust-exposed workers underwent both high-KV radiography and DR to obtain chest radiographs; the image processing parameters were set by the conventional processing method for digital chest radiograph (method A) and the processing method based on the special requirements of occupational diseases (method B).With the high-KV chest radiograph as the reference,the image qualities at 10 anatomic sites of DR image were graded.The images acquired by DR and high-KV radiography were compared,and the DR images acquired by methods A and B were also compared.Results For method A,the scores at the 10 anatomic sites of DR image were mostly 0 and +1,accounting for over 88%,and the mean score was 0.23~0.65,there was a significant difference between the mean score of DR image and the score of high-KV image (P<0.001).For method B,the scores at the 10 anatomic sites of DR image were mostly 0,accounting for over 65%,and the mean score was -0.01~+0.02 except at the pleura and chest wall; there was no significant difference between the mean score of DR image and the score of high-KV image (P>0.05).There were significant differences in the scores at the 10 anatomic sites between the DR images acquired by methods A and B (P<0.01).Conclusion The DR images acquired based on different processing parameters are different.The quality of DR image acquired by the processing method based on the special requirements of occupational diseases is similar to that of high-KV image at the anatomic sites.