目的 建立工作场所空气中1-溴丙烷的气相色谱测定法.方法 应用活性炭管采集工作场所空气中1-溴丙烷,二硫化碳溶剂解吸后,气相色谱-火焰离子化检测器测定,以保留时间定性,以峰面积定量.结果 该方法线性范围为2.50~500.00μg/ml,回归方程为y=3553.4x-10064,相关系数R=0.9998,检出限为0.25 μg/ml,1-溴丙烷最低检出浓度为0.14 mg/m3(以采集1.8L空气样品计).平均加标回收率为96.8%~102.6%,平均解吸效率为93.2%~104.4%,批间和批内相对标准偏差<10%,样品在室温下可保存5d.结论 该方法适用于工作场所空气中1-溴丙烷的测定.
目的 建立工作場所空氣中1-溴丙烷的氣相色譜測定法.方法 應用活性炭管採集工作場所空氣中1-溴丙烷,二硫化碳溶劑解吸後,氣相色譜-火燄離子化檢測器測定,以保留時間定性,以峰麵積定量.結果 該方法線性範圍為2.50~500.00μg/ml,迴歸方程為y=3553.4x-10064,相關繫數R=0.9998,檢齣限為0.25 μg/ml,1-溴丙烷最低檢齣濃度為0.14 mg/m3(以採集1.8L空氣樣品計).平均加標迴收率為96.8%~102.6%,平均解吸效率為93.2%~104.4%,批間和批內相對標準偏差<10%,樣品在室溫下可保存5d.結論 該方法適用于工作場所空氣中1-溴丙烷的測定.
목적 건립공작장소공기중1-추병완적기상색보측정법.방법 응용활성탄관채집공작장소공기중1-추병완,이류화탄용제해흡후,기상색보-화염리자화검측기측정,이보류시간정성,이봉면적정량.결과 해방법선성범위위2.50~500.00μg/ml,회귀방정위y=3553.4x-10064,상관계수R=0.9998,검출한위0.25 μg/ml,1-추병완최저검출농도위0.14 mg/m3(이채집1.8L공기양품계).평균가표회수솔위96.8%~102.6%,평균해흡효솔위93.2%~104.4%,비간화비내상대표준편차<10%,양품재실온하가보존5d.결론 해방법괄용우공작장소공기중1-추병완적측정.
Objective To establish a method for determination 1-bromopropane (1-BP) in workplace air by gas chromatography-flame ionization detector (GC-FID).Method 1-bromopropane in workplace air was collected with activated charcoal tube,then desorbed by carbon disulfide and determined by GC-FID.1-bromopropane was quantitatively measured using retention time and peak area.Results Linear regression formula was Y =3353.4x-10064 in a range of 2.50~500.00 μg/ml with regression coefficient R =0.9998.Detection limit was 0.25 μg/ml and the lowest detection concentration of 1-brmopropane in air was 0.14 mg/m3(at air volume 1.8L).The mean recoveries of 1-BP were between 96.8% and 102.6%,and relative standard deviation of inter and intra-assay was less than 10%.The average desorption efficiencies were between 93.2% and 104.4%.The samples in activated charcoal tube could be stably stored for 5 days at room temperature.Conclusion The method could be feasible to determine 1-bromopropane in workplace air.