搭建了旁路二极管结温测试的两个测试平台,一个是稳态法测试平台,一个是瞬态法测试平台,并在两个平台上进行了多次试验.结果表明,旁路二极管结温测试具有较高的测试不确定性.相对而言,稳态法重复性和稳定性比较高.在保证热阻RTHjc值可靠的情况下,建议采用稳态法进行结温测试.
搭建瞭徬路二極管結溫測試的兩箇測試平檯,一箇是穩態法測試平檯,一箇是瞬態法測試平檯,併在兩箇平檯上進行瞭多次試驗.結果錶明,徬路二極管結溫測試具有較高的測試不確定性.相對而言,穩態法重複性和穩定性比較高.在保證熱阻RTHjc值可靠的情況下,建議採用穩態法進行結溫測試.
탑건료방로이겁관결온측시적량개측시평태,일개시은태법측시평태,일개시순태법측시평태,병재량개평태상진행료다차시험.결과표명,방로이겁관결온측시구유교고적측시불학정성.상대이언,은태법중복성화은정성비교고.재보증열조RTHjc치가고적정황하,건의채용은태법진행결온측시.
According to international standard, two platforms for bypass diode junction temper ature testing were constructed. One was steady state method, and the other was pulsed state method. Several times of tests were carried on in the platform. The results showed that junction temperature test had high uncertainty. Comparatively, the repeatability and stability of steady state method were relatively high. In case of the reliability of the thermal resistance, RTHjc, steady state method was suggested for junction temperature test.