就某炼油厂连续重整装置4M50型往复式氢气压缩机停工检修复工后不上量故障现象进行了描述,结合拆检状况和整个管网系统实际对压缩机不上量原因进行了详细分析,最后给出解决措施.
就某煉油廠連續重整裝置4M50型往複式氫氣壓縮機停工檢脩複工後不上量故障現象進行瞭描述,結閤拆檢狀況和整箇管網繫統實際對壓縮機不上量原因進行瞭詳細分析,最後給齣解決措施.
취모련유엄련속중정장치4M50형왕복식경기압축궤정공검수복공후불상량고장현상진행료묘술,결합탁검상황화정개관망계통실제대압축궤불상량원인진행료상세분석,최후급출해결조시.
The 4M50 type of reciprocating hydrogen compressors at continuous reforming unit of a refinery were in low dis-charge rate after overhauled and returned to work. The failure phenomenon was described in this paper. Combining overhauling condition and the whole pipe network system of the compressor, the reasons were analyzed in detail. Finally the solution mea-sures were provided.