中国医疗器械杂志
中國醫療器械雜誌
중국의료기계잡지
CHINESE JOURNAL OF MEDICAL INSTRUMENTATION
2013年
1期
49-50
,共2页
曹俐%李苗%吴碧涛%吴明军
曹俐%李苗%吳碧濤%吳明軍
조리%리묘%오벽도%오명군
针孔试验%仲裁法%漏水法%电检法
針孔試驗%仲裁法%漏水法%電檢法
침공시험%중재법%루수법%전검법
pinhole test%arbitration method%water leak test%electrical test
设计了漏水法、电检法和改进电检法三种方法的比对针孔检出试验,得出的结论是漏水法最适合作为仲裁法,并建议国家标准中对电检法增加电解液充入量,以提高检测精度.
設計瞭漏水法、電檢法和改進電檢法三種方法的比對針孔檢齣試驗,得齣的結論是漏水法最適閤作為仲裁法,併建議國傢標準中對電檢法增加電解液充入量,以提高檢測精度.
설계료루수법、전검법화개진전검법삼충방법적비대침공검출시험,득출적결론시루수법최괄합작위중재법,병건의국가표준중대전검법증가전해액충입량,이제고검측정도.
Designed a contrast pinhole detect testing including water leak method, electrical method and improved electrical method, and concluded that the water leak method is most suitable as the arbitration method, and recommended the national standard add the requirement on electrolytic liquid fil ing volume of electrical test in order to improve detection accuracy.