针对某厂废气处理装置产品气往复式压缩机连杆螺栓断裂故障,从机组安装及运行出发,结合拆检情况、螺栓断口及受力等综合分析了故障产生原因.
針對某廠廢氣處理裝置產品氣往複式壓縮機連桿螺栓斷裂故障,從機組安裝及運行齣髮,結閤拆檢情況、螺栓斷口及受力等綜閤分析瞭故障產生原因.
침대모엄폐기처리장치산품기왕복식압축궤련간라전단렬고장,종궤조안장급운행출발,결합탁검정황、라전단구급수력등종합분석료고장산생원인.
In view of product gas reciprocating compressor connecting‐rod bolt fracture failure for waste gas treatment unit of a refinery ,the installation and operation status were detailed at first .Then bolt fracture stress was analyzed combining the overhauling condition .The failure cause was comprehensive analyzed and provided finally .