陈晓文%汤毅%卢佳华%阳弘涛
陳曉文%湯毅%盧佳華%暘弘濤
진효문%탕의%로가화%양홍도
剧场%降噪%机电安装%空调系统%噪声测试
劇場%降譟%機電安裝%空調繫統%譟聲測試
극장%강조%궤전안장%공조계통%조성측시
theater%noise reducing%electromechanical installation%air condition system%noise test
为了满足剧场类建筑的功能性和舒适性要求,需在建筑内布置复杂的空调系统和设备,这些设备的运行和建筑的外环境均造成了场内广泛的噪声源,因此,对空调系统内设备的噪声防治就成为保证剧场声学效果的关键。目前,国内外的文献对剧场内空调系统的降噪措施、测试方法及测试数据缺乏详细的资料。本文以上海交响乐团迁建工程为研究背景,详细介绍了该项目机电安装工程中各项空调系统降噪措施的实施,通过实际测试得出了排演厅各测点的噪声均为20dB左右,符合甲等剧院的要求。本文介绍的降噪措施及测试方法希望能对今后类似机电安装工程的实施提供参考。
為瞭滿足劇場類建築的功能性和舒適性要求,需在建築內佈置複雜的空調繫統和設備,這些設備的運行和建築的外環境均造成瞭場內廣汎的譟聲源,因此,對空調繫統內設備的譟聲防治就成為保證劇場聲學效果的關鍵。目前,國內外的文獻對劇場內空調繫統的降譟措施、測試方法及測試數據缺乏詳細的資料。本文以上海交響樂糰遷建工程為研究揹景,詳細介紹瞭該項目機電安裝工程中各項空調繫統降譟措施的實施,通過實際測試得齣瞭排縯廳各測點的譟聲均為20dB左右,符閤甲等劇院的要求。本文介紹的降譟措施及測試方法希望能對今後類似機電安裝工程的實施提供參攷。
위료만족극장류건축적공능성화서괄성요구,수재건축내포치복잡적공조계통화설비,저사설비적운행화건축적외배경균조성료장내엄범적조성원,인차,대공조계통내설비적조성방치취성위보증극장성학효과적관건。목전,국내외적문헌대극장내공조계통적강조조시、측시방법급측시수거결핍상세적자료。본문이상해교향악단천건공정위연구배경,상세개소료해항목궤전안장공정중각항공조계통강조조시적실시,통과실제측시득출료배연청각측점적조성균위20dB좌우,부합갑등극원적요구。본문개소적강조조시급측시방법희망능대금후유사궤전안장공정적실시제공삼고。
To meet the requirement of function and comfort to the theater, many air condition systems and equipment should be arranged into the building. The operation of the equipment and noise of surrounding out of building caused a large origin of noise to theater. Therefore, prevention of noise to air condition systems was a key to commit the effect of acoustics for theater. There was lack of references in reducing technology, testing method and data to noise of air condition in both internal and abroad currently. This paper referred the relocation of Shanghai symphony orchestra project as research background, introduced the methods of noise reducing in air condition system during the electromechanical installation progress. The test showed that the noise of every station in rehearsal room was lower than 20dB and managed the standard of graded A theater. The methods of reducing and testing the noise afforded the reference to the similar electromechanical installation project.