针对VCP槽填孔过程中出现的空洞、凹陷值偏大、漏填等品质缺陷问题,对其产生原因进行深入分析,并通过组织相关测试手段及试验进行验证,试验结果表明:导电性不良,喷嘴堵塞是造成空洞、凹陷值偏大的主要原因。漏填现象发生跟槽液中的气泡有关。
針對VCP槽填孔過程中齣現的空洞、凹陷值偏大、漏填等品質缺陷問題,對其產生原因進行深入分析,併通過組織相關測試手段及試驗進行驗證,試驗結果錶明:導電性不良,噴嘴堵塞是造成空洞、凹陷值偏大的主要原因。漏填現象髮生跟槽液中的氣泡有關。
침대VCP조전공과정중출현적공동、요함치편대、루전등품질결함문제,대기산생원인진행심입분석,병통과조직상관측시수단급시험진행험증,시험결과표명:도전성불량,분취도새시조성공동、요함치편대적주요원인。루전현상발생근조액중적기포유관。
The reasons which led to the quality defects of void, dimple value too large, un-iflling and so on were analyzed deeply in the process of microvia iflling for the VCP bath .At the same time, they were veriifed by using the relevant test methods and experiment.The results showed that the electrical conductivity of collect was poor and some nozzles were blocked, which was the main reason led to the void, dimple value too larger causing the un-iflling phenomenon related to the bubble in bath.