实用医学影像杂志
實用醫學影像雜誌
실용의학영상잡지
JOURNAL OF PRACTICAL MEDICAL IMAGING
2014年
6期
440-441
,共2页
肝脓肿,化脓性%多探头的计算机断层扫描%磁共振成像
肝膿腫,化膿性%多探頭的計算機斷層掃描%磁共振成像
간농종,화농성%다탐두적계산궤단층소묘%자공진성상
Liver abscess,pyogenic%Multidetector computed tomography%Magnetic resonance imaging
目的:采用双排螺旋CT三期增强扫描与低场强磁共振成像(MRI)平扫的诊断方法对肝脓肿炎症期患者进行分析。方法选取2010年1月1日至2013年12月31日在我院经多重方法确诊为肝脓肿炎症期的患者158例,将患者随机分为对照组79例、治疗组79例。给予对照组的肝脓肿炎症期患者采用双排螺旋CT三期增强扫描,给予治疗组肝脓肿炎症期患者采用双排螺旋CT三期增强扫描与低场强MRI平扫。结果使用双排螺旋CT三期增强扫描的对照组79例患者中诊断准确有48例患者,误诊有31例患者,使用双排螺旋CT增强三期增强扫描与低场强MRI平扫的治疗组79例患者中诊断准确有72例患者,误诊7例患者。治疗组的准确率(91.1%)明显好于对照组的准确率(60.8%),两组比较具有统计学意义(P<0.05)。结论采用双排螺旋CT三期增强扫描与低场强MRI平扫对肝脓肿炎症期患者进行诊断分析有较高的准确率,能够降低误诊率,可以广泛的应用于临床的检查中,值得大力推广。
目的:採用雙排螺鏇CT三期增彊掃描與低場彊磁共振成像(MRI)平掃的診斷方法對肝膿腫炎癥期患者進行分析。方法選取2010年1月1日至2013年12月31日在我院經多重方法確診為肝膿腫炎癥期的患者158例,將患者隨機分為對照組79例、治療組79例。給予對照組的肝膿腫炎癥期患者採用雙排螺鏇CT三期增彊掃描,給予治療組肝膿腫炎癥期患者採用雙排螺鏇CT三期增彊掃描與低場彊MRI平掃。結果使用雙排螺鏇CT三期增彊掃描的對照組79例患者中診斷準確有48例患者,誤診有31例患者,使用雙排螺鏇CT增彊三期增彊掃描與低場彊MRI平掃的治療組79例患者中診斷準確有72例患者,誤診7例患者。治療組的準確率(91.1%)明顯好于對照組的準確率(60.8%),兩組比較具有統計學意義(P<0.05)。結論採用雙排螺鏇CT三期增彊掃描與低場彊MRI平掃對肝膿腫炎癥期患者進行診斷分析有較高的準確率,能夠降低誤診率,可以廣汎的應用于臨床的檢查中,值得大力推廣。
목적:채용쌍배라선CT삼기증강소묘여저장강자공진성상(MRI)평소적진단방법대간농종염증기환자진행분석。방법선취2010년1월1일지2013년12월31일재아원경다중방법학진위간농종염증기적환자158례,장환자수궤분위대조조79례、치료조79례。급여대조조적간농종염증기환자채용쌍배라선CT삼기증강소묘,급여치료조간농종염증기환자채용쌍배라선CT삼기증강소묘여저장강MRI평소。결과사용쌍배라선CT삼기증강소묘적대조조79례환자중진단준학유48례환자,오진유31례환자,사용쌍배라선CT증강삼기증강소묘여저장강MRI평소적치료조79례환자중진단준학유72례환자,오진7례환자。치료조적준학솔(91.1%)명현호우대조조적준학솔(60.8%),량조비교구유통계학의의(P<0.05)。결론채용쌍배라선CT삼기증강소묘여저장강MRI평소대간농종염증기환자진행진단분석유교고적준학솔,능구강저오진솔,가이엄범적응용우림상적검사중,치득대력추엄。
Objective With double row of three periods of spiral CT enhancement scanning with low field strength MRI scan diagnosis in patients with liver abscess inflammation period were analyzed. Methods Selection on January 1, 2010 to December 31, 2013 in our hospital by the method of multiple diagnosis of liver abscess patients with inflammation of 158 cases, patients were randomly divided into the control group 79 cases, and the treatment group 79 cases. Phase to control inflammation of the liver abscess were treated by three periods of double row spiral CT enhanced scan, give treatment group phase inflammation of liver abscess were treated by three periods of double row spiral CT enhancement scanning with low field strength MRI scan. Results Three periods of using double row spiral CT enhancement scanning in the control group, 48 patients diagnosis were accurate, 31 patients were misdiag-nosed. Using three phase of double row spiral CT enhancement scanning with low field strength MRI scan of the treatment group, there are 7 patients were misdiagnosed in 79 patients. Accuracy (91.1%) of treatment group was ob-viously better than the control group (60.8%), comparing the two groups have statistical significance ( P<0.05). Con-clusion The double row of three periods of spiral CT enhancement scanning with low field strength MRI scan on the diagnosis to patients with liver abscess inflammation period analysis is with high accuracy. It can reduce the misdiag-nosis rate, and can be widely applied to clinical examination, is worth promoting.