目的:探讨XN‐1000希森美康细胞分析仪对孕妇外周静脉血白细胞分类计数、有核红细胞计数分析提示与相关细胞涂片染色人工分析结果相关性及意义。方法采用XN‐1000型希森美康细胞分析仪对妇产科采集的280份外周静脉血进行白细胞分类计数、有核红细胞计数分析,同时对应外周静脉血标本进行细胞涂片染色分析,比较仪器分析和细胞染色人工分析结果。结果仪器分析重复性良好,仪器分析和细胞染色人工分析具有较高的相关性,报警提示结果和细胞染色人工分析阳性结果特异性大于95%,灵敏度100%,阳性预测值大于90%,阴性预测值100.00%。结论 XN‐1000希森美康细胞分析仪分析报警提示可以有效筛选阳性标本,同时对阳性标本需要细胞染色人工分析,避免假阳性结果。
目的:探討XN‐1000希森美康細胞分析儀對孕婦外週靜脈血白細胞分類計數、有覈紅細胞計數分析提示與相關細胞塗片染色人工分析結果相關性及意義。方法採用XN‐1000型希森美康細胞分析儀對婦產科採集的280份外週靜脈血進行白細胞分類計數、有覈紅細胞計數分析,同時對應外週靜脈血標本進行細胞塗片染色分析,比較儀器分析和細胞染色人工分析結果。結果儀器分析重複性良好,儀器分析和細胞染色人工分析具有較高的相關性,報警提示結果和細胞染色人工分析暘性結果特異性大于95%,靈敏度100%,暘性預測值大于90%,陰性預測值100.00%。結論 XN‐1000希森美康細胞分析儀分析報警提示可以有效篩選暘性標本,同時對暘性標本需要細胞染色人工分析,避免假暘性結果。
목적:탐토XN‐1000희삼미강세포분석의대잉부외주정맥혈백세포분류계수、유핵홍세포계수분석제시여상관세포도편염색인공분석결과상관성급의의。방법채용XN‐1000형희삼미강세포분석의대부산과채집적280빈외주정맥혈진행백세포분류계수、유핵홍세포계수분석,동시대응외주정맥혈표본진행세포도편염색분석,비교의기분석화세포염색인공분석결과。결과의기분석중복성량호,의기분석화세포염색인공분석구유교고적상관성,보경제시결과화세포염색인공분석양성결과특이성대우95%,령민도100%,양성예측치대우90%,음성예측치100.00%。결론 XN‐1000희삼미강세포분석의분석보경제시가이유효사선양성표본,동시대양성표본수요세포염색인공분석,피면가양성결과。
Objective To investigate the correlation between the analysis prompts of white blood cells (WBC) count and nucleated red blood cells (NRBC) count by the XN‐1000 Sysmex hematology analyzer and the related blood cell smear staining artificial analysis for peripheral venous blood in pregnant women .Methods 280 specimens of pe‐riphery venous blood from pregnant women in our hospital were collected and simultaneously detected the WBC count and NRBC count by using the XN‐1000 Sysmex hematology analyzer and the blood cell smear staining analysis .Then the detection results were compared between the two kinds of detection method .Results The instrumental analysis had good reproducibility .The higher correlation existed between the instrumental analysis and blood cell staining arti‐ficial analysis .The specificity of alarm suggesting analysis results and the positive results of the cell staining artificial analysis was greater than 95% ,the sensitivity was 100% ,the positive prediction value was greater than 90% and the negative prediction value was 100 .00% .Conclusion The analysis alarm prompts of the XN‐1000 Sysmex hematology analyzer can effectively screen the positive samples ,at the same time the positive samples need to conduct the cell staining artificial analysis for avoiding the false positive results .