目的:比较应用微创可调式接骨板联合单枚骶髂螺钉与2枚骶髂螺钉固定骨盆后环对骨盆应力分布的影响。方法选取5具防腐成年男性骨盆标本,保留 L4至双侧股骨近端1/3,剔除软组织,保留完整的耻骨联合、双侧骶髂关节及周围韧带、双侧髋关节、双侧骶结节韧带、双侧骶棘韧带,黏贴应变片。将标本置于 BOSE 生物力学试验机,模拟双足站立中立位,垂直加载负荷至520 N,记录完整骨盆的应变值。制作 Tile C 型骨盆骨折模型,耻骨联合用钢板固定,后环骨折复位后依次应用2种方法进行固定。分别记录2种内固定方法固定骨盆后环时的应变值。结果完整骨盆在垂直负荷下,同一标本两侧对应位点的应变值差异无统计学意义(P >0.05),应变集中位点沿骶股弓走行分布。与完整骨盆的应变值相比,2种方法固定的骨盆后环,除位点5、6、10、11外,其余位点差异无统计学意义(P >0.05)。在500 N垂直负荷下,应用微创可调式接骨板联合单枚骶髂螺钉固定的骨盆各位点应变值更接近完整骨盆的应变值。结论完整骨盆在垂直负荷下的传导与骶股弓走行大致相同。应用微创可调式接骨板联合单枚骶髂螺钉固定骨盆后环比单纯使用2枚骶髂螺钉能更好地恢复力学的传导。
目的:比較應用微創可調式接骨闆聯閤單枚骶髂螺釘與2枚骶髂螺釘固定骨盆後環對骨盆應力分佈的影響。方法選取5具防腐成年男性骨盆標本,保留 L4至雙側股骨近耑1/3,剔除軟組織,保留完整的恥骨聯閤、雙側骶髂關節及週圍韌帶、雙側髖關節、雙側骶結節韌帶、雙側骶棘韌帶,黏貼應變片。將標本置于 BOSE 生物力學試驗機,模擬雙足站立中立位,垂直加載負荷至520 N,記錄完整骨盆的應變值。製作 Tile C 型骨盆骨摺模型,恥骨聯閤用鋼闆固定,後環骨摺複位後依次應用2種方法進行固定。分彆記錄2種內固定方法固定骨盆後環時的應變值。結果完整骨盆在垂直負荷下,同一標本兩側對應位點的應變值差異無統計學意義(P >0.05),應變集中位點沿骶股弓走行分佈。與完整骨盆的應變值相比,2種方法固定的骨盆後環,除位點5、6、10、11外,其餘位點差異無統計學意義(P >0.05)。在500 N垂直負荷下,應用微創可調式接骨闆聯閤單枚骶髂螺釘固定的骨盆各位點應變值更接近完整骨盆的應變值。結論完整骨盆在垂直負荷下的傳導與骶股弓走行大緻相同。應用微創可調式接骨闆聯閤單枚骶髂螺釘固定骨盆後環比單純使用2枚骶髂螺釘能更好地恢複力學的傳導。
목적:비교응용미창가조식접골판연합단매저가라정여2매저가라정고정골분후배대골분응력분포적영향。방법선취5구방부성년남성골분표본,보류 L4지쌍측고골근단1/3,척제연조직,보류완정적치골연합、쌍측저가관절급주위인대、쌍측관관절、쌍측저결절인대、쌍측저극인대,점첩응변편。장표본치우 BOSE 생물역학시험궤,모의쌍족참립중립위,수직가재부하지520 N,기록완정골분적응변치。제작 Tile C 형골분골절모형,치골연합용강판고정,후배골절복위후의차응용2충방법진행고정。분별기록2충내고정방법고정골분후배시적응변치。결과완정골분재수직부하하,동일표본량측대응위점적응변치차이무통계학의의(P >0.05),응변집중위점연저고궁주행분포。여완정골분적응변치상비,2충방법고정적골분후배,제위점5、6、10、11외,기여위점차이무통계학의의(P >0.05)。재500 N수직부하하,응용미창가조식접골판연합단매저가라정고정적골분각위점응변치경접근완정골분적응변치。결론완정골분재수직부하하적전도여저고궁주행대치상동。응용미창가조식접골판연합단매저가라정고정골분후배비단순사용2매저가라정능경호지회복역학적전도。
Objective To compare the stress distribution of posterior pelvic ring fixed with minimally invasive adjustable plate(MIAP)combined with one iliosacral(IS)screw and two IS screws.Methods Five embalmed specimens of adult pelvis were used.The soft tissue was removed from the specimens,and the spines from the fourth lumbar vertebra to the proximal one-third of both femurs were retained.The pubic symphysis,bilateral sacroiliac joints and ligments, bilateral hip joints,bilateral sacrotuberous ligaments and sacrospinous ligaments were intact.The strain gages were adhered to 32 sites distributed symmetrically.The specimens were placed in the biomecanical machine at a standing neutral posture.Vertical load up to 520 N was applied and the strain value of intact pelvic ring was recorded.The Tile C pelvic fractures were made.The symphysis pubis was fixed with plate,and the fracture of posterior pelvic ring was fixed with two kinds of internal fixators.The strain changes were recorded respectively.Results The symmetrical sites of the intact pelvic ring had similar strain changes(P >0.05).And the strain concentration sites ran along the sacrofemoral arch.Compared with the strain value of the intact pelvis,the strain changes of these sites(except site 5,6,10,11)in the pelvic fractures fixed with two kinds of internal fixation were not statistically significant(P > 0.05).Each strain value in the posterior pelvic ring fixed with MIAP combined with one IS screw was close to that in intact pelvis under 500 N vertical load.Conclusion In the intact pelvic ring,the conduction of vertical load runs along the sacrofemoral arch.The posterior pelvic ring fixed with MIAP combined with one IS screw can achieve better restoration of mechanical conduction than that fixed with two IS screws.