制冷技术
製冷技術
제랭기술
REFRIGERATION TECHNOLOGY
2014年
6期
53-57
,共5页
污水源热泵%热泵机组%供热性能
汙水源熱泵%熱泵機組%供熱性能
오수원열빙%열빙궤조%공열성능
Sewage source heat pump%Heat pump unit%Heating performance
以哈尔滨市应用的某污水源热泵为例,通过应用实际测试的方法,分析了污水热能利用情况及系统供热过程中热泵机组的供热性能。结果表明:在测试期间,室内外温差很大的情况下,污水源热泵仍能满足供热要求,具有良好的稳定性。热泵机组的平均供热性能系数为2.92。
以哈爾濱市應用的某汙水源熱泵為例,通過應用實際測試的方法,分析瞭汙水熱能利用情況及繫統供熱過程中熱泵機組的供熱性能。結果錶明:在測試期間,室內外溫差很大的情況下,汙水源熱泵仍能滿足供熱要求,具有良好的穩定性。熱泵機組的平均供熱性能繫數為2.92。
이합이빈시응용적모오수원열빙위례,통과응용실제측시적방법,분석료오수열능이용정황급계통공열과정중열빙궤조적공열성능。결과표명:재측시기간,실내외온차흔대적정황하,오수원열빙잉능만족공열요구,구유량호적은정성。열빙궤조적평균공열성능계수위2.92。
Taking the sewage source heat pump applied in Harbin as an example, the utilization of sewage energy and the heating performance of heat pump unit during the system heating progress was analyzed by the actual test way. The results show that, at the test period and under the condition of large difference between indoor temperature and outdoor temperature, the sewage source heat pump still satisfy the heating quest and have a good stability. The average heating performance of the heat pump unit is 2.92.