针对元宝山电厂亚临界600 MW机组塔式直流锅炉炉内结焦严重、“四管”泄漏频繁、过热器再热器超温、制粉系统出力不足等问题,对该机组锅炉水冷壁进行了优化改造。根据改造后的锅炉水冷壁结构特点及炉内热负荷分布特点,将水冷壁划分为由流量回路、压力节点和连接管组成的流动网络系统,根据质量守恒、动量守恒和能量守恒方程,建立了亚临界锅炉流量分配及出口汽温的计算模型。在此基础上对锅炉在不同工况时各回路流量分配及壁温分布进行了计算。结果表明,在TRL、75%TRL及30%TRL工况下,管内、外壁温度、壁厚中间点温度和鳍端温度均处于管子的允许温度范围之内,可以保证锅炉的安全运行。
針對元寶山電廠亞臨界600 MW機組塔式直流鍋爐爐內結焦嚴重、“四管”洩漏頻繁、過熱器再熱器超溫、製粉繫統齣力不足等問題,對該機組鍋爐水冷壁進行瞭優化改造。根據改造後的鍋爐水冷壁結構特點及爐內熱負荷分佈特點,將水冷壁劃分為由流量迴路、壓力節點和連接管組成的流動網絡繫統,根據質量守恆、動量守恆和能量守恆方程,建立瞭亞臨界鍋爐流量分配及齣口汽溫的計算模型。在此基礎上對鍋爐在不同工況時各迴路流量分配及壁溫分佈進行瞭計算。結果錶明,在TRL、75%TRL及30%TRL工況下,管內、外壁溫度、壁厚中間點溫度和鰭耑溫度均處于管子的允許溫度範圍之內,可以保證鍋爐的安全運行。
침대원보산전엄아림계600 MW궤조탑식직류과로로내결초엄중、“사관”설루빈번、과열기재열기초온、제분계통출력불족등문제,대해궤조과로수랭벽진행료우화개조。근거개조후적과로수랭벽결구특점급로내열부하분포특점,장수랭벽화분위유류량회로、압력절점화련접관조성적류동망락계통,근거질량수항、동량수항화능량수항방정,건립료아림계과로류량분배급출구기온적계산모형。재차기출상대과로재불동공황시각회로류량분배급벽온분포진행료계산。결과표명,재TRL、75%TRL급30%TRL공황하,관내、외벽온도、벽후중간점온도화기단온도균처우관자적윤허온도범위지내,가이보증과로적안전운행。
Such problems as serious salgging,frequent tube burst,superheater and reheater overtemperature and insufficient pulverizing system capacity occurred in the 600 MW unit once-through tower boiler in Yuanbaoshan Power Plant.Thus,the water wall of this boiler was optimized.According to the structural characteristics of the water wall and the heat load distribution features in the furnace after the transforma-tion,the water wall was divided into the flow circuit,pressure point and flow network system comprised of connected tubes.On the basis of the mass conservation equation,momentum balance equation and energy conservation equation,the mathematic models for pressure drop and outlet steam temperature of water wall tube in subcritical boiler were established.Moreover,the total pressure drop in rising system and the outlet steam temperature of the upper and lower water wall were calculated,under conditions with different unit loads.The results show that,the temperature of the inner pipes,outer pipes,middle points and the rear fin are all reliable,which can ensure the boiler work safely.