分析并消除以电感耦合等离子体质谱(ICP-MS)法测定化妆品中汞含量时干扰因素对结果的影响。考察了不同质量数对测定结果的影响,采用204作为汞测定质量数,测定化妆品中的汞含量,有效消除了质谱型干扰,加样回收率为100.4%~104.2%。测定结果用冷原子吸收法加以验证,结果满意。
分析併消除以電感耦閤等離子體質譜(ICP-MS)法測定化妝品中汞含量時榦擾因素對結果的影響。攷察瞭不同質量數對測定結果的影響,採用204作為汞測定質量數,測定化妝品中的汞含量,有效消除瞭質譜型榦擾,加樣迴收率為100.4%~104.2%。測定結果用冷原子吸收法加以驗證,結果滿意。
분석병소제이전감우합등리자체질보(ICP-MS)법측정화장품중홍함량시간우인소대결과적영향。고찰료불동질량수대측정결과적영향,채용204작위홍측정질량수,측정화장품중적홍함량,유효소제료질보형간우,가양회수솔위100.4%~104.2%。측정결과용랭원자흡수법가이험증,결과만의。
To analyze and eliminate the interference in determination of mercury in cosmetics by ICP-MS,the influences of dif-ferent mass numbers on the determination results were investigated.Mercury in cosmetics was determined by ICP-MS with 204 as mass number,which effectively eliminated the mass interference.The recoveries were in the range of 100.4% to 104.2%. Determination results were satisfactory,which were also verified by cold atomic absorption spectrometry.