灰水泵%变频%节能%分析
灰水泵%變頻%節能%分析
회수빙%변빈%절능%분석
ash water pump%frequency conversion%energy saving%analysis
针对气化工序灰水系统高压灰水泵设计裕量偏大、运行效率低、电耗高、回流管线振动大的问题,将高压灰水泵改为变频调节。改造后,在2台气化炉运行的工况下,回流减压阀全关,电机电流由改造前的140 mA左右降至95 mA左右,节能效果非常明显,回流管线振动大的问题也随之解决。
針對氣化工序灰水繫統高壓灰水泵設計裕量偏大、運行效率低、電耗高、迴流管線振動大的問題,將高壓灰水泵改為變頻調節。改造後,在2檯氣化爐運行的工況下,迴流減壓閥全關,電機電流由改造前的140 mA左右降至95 mA左右,節能效果非常明顯,迴流管線振動大的問題也隨之解決。
침대기화공서회수계통고압회수빙설계유량편대、운행효솔저、전모고、회류관선진동대적문제,장고압회수빙개위변빈조절。개조후,재2태기화로운행적공황하,회류감압벌전관,전궤전류유개조전적140 mA좌우강지95 mA좌우,절능효과비상명현,회류관선진동대적문제야수지해결。
In connection with problems of high pressure ash water pump of ash water system in gasification process, such as large design margin, low operation efficiency, high electricity consumption, and excessive vibration of reflux lines, the adjustment of high pressure ash water pump is changed to frequency conversion adjustment.After renovation, in operation conditions of 2 gasifiers, pressure reducing valves are all closed, motor current is reduced from about 140 mA before renovation to about 95 mA, having significant energy saving effect, and the problem of heavy vibration of reflux lines is solved.